Loading...
2018-145 Landfill Landscape Buffer and Tree Planting UpdateDate: October 5, 2018 Report No. 2018-145 INFORMAL STAFF REPORT TO MAYOR AND CITY COUNCIL SUBJECT: Update on landfill landscape buffer and tree planting BACKGROUND: During the October 16, 2018 City Council meeting, the Council will be asked to consider approval of a contract with Fannin Tree Farm Sales, LLC for the supply and installation of trees for City of Denton parks, medians, right of ways, and public buildings (Item 18-1669). The proposed purchase agreement, totaling $1,206,000 over four (4) years, includes $406,000 to install trees as part of a landscape buffer surrounding the Solid Waste Department’s landfill operation. The below report provides a summary of the department’s buffer zone standards and an overview of plans to improve the landscape buffer. LANDSCAPE BUFFER: In solid waste operations, buffer zones are typically utilized to restrict residential or commercial use of property within a certain distance of waste disposal activity. For the Solid Waste Department’s waste disposal operation, the buffer is 115 feet wide and runs parallel along Mayhill Road from Edwards Road to Foster Road. An additional 100 foot wide buffer runs along Edwards Road. The Solid Waste Department’s buffer zone includes landscaping and other screening to separate operational activities from adjacent properties. The standards for maintaining the buffer zone are outlined within Solid Waste’s Specific Use Permit S-204. The permit requires “sufficient landscaping and screening to ensure harmony and compatibility with adjacent property.” Following the Texas Commission on Environmental Quality’s approval of Permit No. MSW 1590-A in 1999, the Solid Waste Department installed an appropriate landscape buffer; however, portions of the vegetation died in the years that followed. Earlier this year, staff partnered with Freese & Nichols to redesign the landscape buffer and irrigation system. The purpose of this effort was to create a design that remediates trees lost in recent years while working around obstructions related to existing utility infrastructure, a future DME transmission project, and Mayhill Road realignment. The planting and irrigation project is broken into phases. Designs for the first two phases of the project are complete, and the proposed contract with Fannin Tree Farm allows for the purchase of 358 trees annually. Staff’s goals are to remediate 100% of previous onsite tree loss (approximately 560 trees), and capitalize on opportunities to plant elsewhere onsite. Date: October 5, 2018 Report No. 2018-145 TREE PLANTING SCHEDULE: Because landscape design and tree planting is being attempted while several construction projects are occurring in the area, the tree planting project is occurring in phases. Below is a brief overview of each phase and the developments that must occur before final planting and irrigation:  Phase 1– Located between the westernmost inactive landfill cell and the recently installed screening wall, Solid Waste is anticipating the installation 90 canopy trees and 88 understory trees and plants consistent with a June 2018 design by Freese and Nichols (Exhibit 1). Mobilization and tree installation is anticipated promptly (fall 2018), once the proposed contract is approved. Installation of the permanent irrigation system will occur with Phase 2 and 3. As a result, a temporary irrigation system will be installed as part of Phase 1.  Phase 2 – Located in the eastern public way approximately along Mayhill Road, from approximately Foster Rd to Old Edwards Road, Solid Waste is anticipating the installation 39 canopy trees and 144 understory trees and plants consistent with an August 2018 design by Freese and Nichols (Exhibit 2). Mobilization and installation of trees and irrigation will occur upon the completion of the Mayhill Road realignment and the installation of transmission lines associated with a DME capital project.  Phase 3 – Located in the public way adjacent to reconstructed Mayhill Rd. South of Old Edwards Rd. Once the final alignment and subsequent design of Mayhill Road south of Old Edwards Rd. is complete, landscape design will proceed, and installation will commence as road construction is completed. Please feel free to contact me if you have additional questions or concerns. ATTACHMENT(S): Exhibit 1 – Phase One Landfill Buffer Landscape Design Exhibit 2 – Phase Two Landfill Buffer Landscape Design STAFF CONTACT(S): Ethan Cox, Director of Solid Waste (940) 349-7421 Ethan.Cox@cityofdenton.com Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:15:07 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD-P1-CV-COVER.sht9999.9800 ft / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:15:07 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD-P1-CV-COVER.shtProject:Mayhill SouthDefaultModel:DTN18117 CITY OF DENTON, TEXAS LOCATION PROJECT COUNCIL MEMBER.........................SARA BAGHERI COUNCIL MEMBER......................DALTON GREGORY COUNCIL MEMBER..........................JOEY HAWKINS COUNCIL MEMBER................KATHLEEN WAZNEY COUNCIL MEMBER............................KEELY BRIGGS COUNCIL MEMBER.............................KEVIN RODEN MAYOR.....................................................CHRIS WATTS 8000'4000'0 SCALE IN FEET JUNE 2018 TEXAS REGISTERED ENGINEERING FIRM F-2144 CITY MANAGER.................................TODD HILEMAN CITY ENGINEER.................................FRANK G. PAYNE, P.E. PHASE ONE LANDFILL BUFFER LANDSCAPE DESIGN PLANTING LISTLA-5 PLANTING DETAILSLA-4 LANDSCAPE PLANTING PLANLA-3 LANDSCAPE PLANTING PLANLA-2 ORIENTATION PLANLA-1 SHEET INDEX NOT FOR CONSTRUCTION DATE: THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW UNDER THE NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. AUTHORITY OF MATTHEW L. MILANO TEXAS NO: 3028 JUNE 2018 ISSUED FOR REVIEW IR-1 IRRIGATION PLANS IR-2 IRRIGATION PLANS IR-3 IRRIGATION DETAILS I IR-4 IRRIGATION DETAILS II IR-1 IRRIGATION PLANS IR-2 IRRIGATION PLANS IR-3 IRRIGATION DETAILS I IR-4 IRRIGATION DETAILS II F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- CV-P1-KEYMAP.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 05:06:42 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- CV-P1-KEYMAP.sht159.9997 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 05:06:42 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- CV-P1-KEYMAP.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNGWSGWSGWS PROPOSED S MAYHILL ROAD LA-2 LA-2 LA-3 LA-3 NOT FOR CONSTRUCTIONDATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THENOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTION.AUTHORITY OF MATTHEW L. MILANOTEXAS NO: 3028JUNE 2018HHEAFEAFMLMLANDSCAPE ARCHITECTUREORIENTATION PLANLA-1PHASE ONE160'80'0 40' SCALE IN FEET 1 OF 5 PHASE ONE PHASE TWO F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P1-LANDSCAPE 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:41:42 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 01.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:41:42 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNWVFL=600.68Silted inICV610'595' 6 0 0' 595' 600'600'605'600'605'WVFL=592.9424"PVCFL=592.00FL=592.26WV0595 '600'605'BUFFER LIMIT 54' LANDSCAPE BUFFER LIMIT 54' LANDSCAPE 100'-0"10' O.C. TYP. 10' O.C. TYP. 100'-0" SPECIES TREE TYP. 20' O.C. TYP. 15' O.C. EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING METAL FENCE EXISTING METAL FENCE MLMEAFMLMLA-2 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5 40'20'0 10' SCALE IN FEET LEGEND UNDERSTORY TREE CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3028JUNE 2018MATTHEW L. MILANO7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER. PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES. 6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE 5. DO NOT REMOVE ANY EXISTING TREES. 4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION. 3. REFER TO SHEET LA-4 FOR PLANTING DETAILS. 2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION. 1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE. GENERAL NOTES MATCHLINE BMATCHLINE AMATCHLINE AXX CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CECECECECECECECECECECECECECECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE PHASE ONECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P1-LANDSCAPE 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:16:18 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 02.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:16:18 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 02.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNICVICVICV610'615'WVWV615'620'615'620'615' BUFFER LIMIT 54' LANDSCAPE 10' O.C. TYP. 100'-0" 10' O.C. TYP. TYP. 20' O.C. TYP. 15' O.C. 100'-0" SPECIES TREE BUFFER LIMIT 54' LANDSCAPE EXISTING METAL FENCE TYP. 20' O.C. TYP. 15' O.C. EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING METAL FENCE MLMEAFMLMLA-3 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF3 OF 5 40'20'0 10' SCALE IN FEET LEGEND UNDERSTORY TREE CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018MATCHLINE CMATCHLINE BMATCHLINE C7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER. PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES. 6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE 5. DO NOT REMOVE ANY EXISTING TREES. 4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION. 3. REFER TO SHEET LA-4 FOR PLANTING DETAILS. 2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION. 1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE. GENERAL NOTES TO REMAIN EXISTING TREE XX CECECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE PHASE ONE F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P1-PLANT.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:31:09 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANT.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:31:09 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANT.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNPLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH SURFACE LAYER PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT TREE CENTERED IN HOLE NOTES: 1.TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM COVERAGE. (SEE PLANS FOR TREE LOCATIONS) PLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT PLANTING SOIL MIXTURE EQUALS THREE (3) PARTS EXISTING SOIL AND ON (1) PART FINELY GROUND HARDWOOD MULCH, THOROUGHLY MIXED TREE CENTERED IN HOLE 1/2 INCH DIA. X 36 INCH LONG NAIL STAKES WITH ANGLED TIP AT BOTTOM MULCH TO BE PLACED 3" AWAY FROM TREE TRUNK PLANTING SOIL MIXTURE EQUALS THREE (3) PARTS EXISTING SOIL AND ON (1) PART FINELY GROUND HARDWOOD MULCH, THOROUGHLY MIXED (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL NOTES: WITH THE CITY. INSTALLATION SHALL BE COORDINATED 2. ALL TREE PRUNING AT THE TIME OF SEASON. REMOVED AFTER ONE FULL GROWING ANCHORS AND ARBOR TIE TO BE 1. TEMPORARY TREE WELL, TREE (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL PLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT UNDISTURBED SUBGRADE TREE CENTERED IN HOLE NOTES: LOCATIONS) COVERAGE. (SEE PLANS FOR HARDWOOD MULCH BED RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM 1. TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO 1'-0"3" MIN.6" (TYP.) 6" (TYP.)3" MIN.1'-0" 6" (TYP.)3" MIN.1'-0"MLMEAFMLMLA-4LANDSCAPE ARCHITECT EAF4 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING DETAILSON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE ON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE 1 NOT TO SCALELA-4 2 NOT TO SCALELA-4 CANOPY TREE PLANTING AND STAKING DETAIL 3 NOT TO SCALELA-4 UNDERSTORY EVERGREEN TREE PLANTING AND STAKING DETAIL UNDERSTORY MULTI-TRUNK TREE PLANTING AND STAKING DETAIL ON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE PHASE ONET-POSTS F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P1-PLANTLIST.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:25:40 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANTLIST.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:25:40 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANTLIST.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN PLANT SCHEDULE SYMBOL PERCENTAGE SIZE COMMON NAME BOTANICAL NAME CONDITION COMMENTS CANOPY TREE SG #65 CLASS MINIMUM SWEETGUM LIQUIDAMBER STYRACIFLUA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE RC #65 CLASS MINIMUM RED CEDAR JUNIPERUS VIRGINIANA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE AP #65 CLASS MINIMUM AFGHAN PINE PINUS ELDARICA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE BO #65 CLASS MINIMUM BURR OAK QUERCUS MACCROCARPA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE LE #65 CLASS MINIMUM LACEBARK ELM ULUMUS PARVIFOLIA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE PE #65 CLASS MINIMUM PECAN CARYA ILLINOISENSIS CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE RB #65 CLASS MINIMUM RIVER BIRCH BETULA NIGRA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE UNDERSTORY TREE AV #45 CLASS MINIMUM ARBOR VITAE THUGA ACCIDENTAILS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH EP #45 CLASS MINIMUM EAST PALATKA HOLLY ILEX EAST PALATKA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH MR #45 CLASS MINIMUM MEXICAN/ OKLAHOMA REDBUD MEXICANA OR 'OKLAHOMA' CERCIC CANADENSIS VAR. CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH MP #45 CLASS MINIMUM MEXICAN PLUM PRUNUS MEXICANA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH SH #45 CLASS MINIMUM STEVENS HOLLY ILEX NELLI R STEVENS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH PH #45 CLASS MINIMUM POSSUMHAW HOLLY ILEX DECIDUA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH INDICATED IN THE PLANT LIST MAY BE NECESSARY TO PROVIDE THE OTHER MINIMUM CRITERIA INDICATED. CRITERIA REQUIRED. A CONTAINER SIZE LARGER THAN THE MINIMUM SIZE CONTAINER MINIMUM1). ALL SIZES SHOWN FOR ALL PLANTS (SUCH AS CALIPER, CONTAINER SIZE, SPREAD, HEIGHT, BRANCHING HEIGHT, ETC.) ARE THE NOTE: MLMEAFMLMLA-5LANDSCAPE ARCHITECT EAF5 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING LIST18 18 18 9 9 9 8 22 22 13 13 9 9 PHASE ONE F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P1-Irrigation 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$Jun. 14, 2018 - 07:51:10 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 01.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 07:51:10 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNWVWVutilityvaultICVmonitoringwellmonitoringwellFL=600.68Silted inWVWarning SignFiber OpticMarkerWater LineMarkerWater LineFL=592.9424"PVCFL=592.00FL=592.26monitoringwellWV0WVWVutilityvaultICVmonitoringwellmonitoringwellM WVmonitoringwellWV0EXISTING RETAINING WALL EXISTING RETAINING WALL EXISTING METAL FENCE EXISTING METAL FENCE CONTROLLER IRRIGATION IRRIGATION PHASE 1 FOR VALVE ISOLATION REUSE WATER SUPPLY TO BE USED FOR IRRIGATION FIELD VERIFY LOCATION OF EXISTING PHASE 2 IRRIGATION ISOLATION VALVES FOR RJKTMGTMGIR-1 TMG- OF - 40'20'0 10' SCALE IN FEETMATCHLINE BMATCHLINE AMATCHLINE APHASE ONEIRRIGATIONIRRIGATION PLANGENERAL NOTES: NOTE BY SYMBOL " ": 2 3 TYP. 3 TYP. 2 2 NOTE TO CONTRACTOR PRIOR TO CONSTRUCTION DEPARTMENT FOR APPROVAL PLANS TO PERMIT IRRIGATOR MUST SUBMIT REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1. 2 2 3TYP. 3 TYP. PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.3. AND ROADWAYS PER CITY OF DENTON STANDARDS. MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 2. REUSE WATER SUPPLY PER CITY OF DENTON STANDARDS. IRRIGATION SYSTEM WATER SUPPLY. TAP INTO 1.DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P1-Irrigation 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 07:57:32 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 02.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 07:57:32 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 02.shtProject:Mayhill SouthDefaultModel:DTN18117Warning SignFiber OpticICVICVICVmonitoringwellWVWVmonitoringwellWVWVmonitoringwellICVICVICVmonitoringwellEXISTING METAL FENCE EXISTING RETAINING WALL STATION VALVE MLMEAFMLMIR-2 EAF- OF - 40'20'0 10' SCALE IN FEETMATCHLINE CMATCHLINE BMATCHLINE CIRRIGATIONIRRIGATION PLANSNOTE BY SYMBOL " ": NOTE TO CONTRACTOR PRIOR TO CONSTRUCTION DEPARTMENT FOR APPROVAL PLANS TO PERMIT IRRIGATOR MUST SUBMIT 2 TYP. 2 TYP. 2 GENERAL NOTES: REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1. 2 TYP. PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2. AND ROADWAYS PER CITY OF DENTON STANDARDS. MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1. TYP. 1 1 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE 1 XFS-CV ON-SURFACE DRIPLINE INSERT ADAPTER FOR 1" OR LARGER PVC 3 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE MULTIPLE TREE RING LAYOUT SIDE FED 2 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE QUICK LOOP LAYOUT-MEDIAN ISLAND DOWN SLOPE 2"-4"F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail01.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017N.T.S. 4 3 2 1 1 2 OF DIRECTION. OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE 2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES LOAM, AND FIVE FEET IN CLAY. 1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN NOTES: 3 4 5 6 7 6 5 10 8 7 98 109 N.T.S. FP FP FP 1 2 3 4 5 6 7 8 9 OP 1 2 3 4 5 6 7 89 10 11 10 11 NOTES: 1.FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS 2.SEE XFS-CV TREE RING DOUBLE OR TRIPLE FOR DETAIL OF EACH SET OF RINGS. 3.FOR TOTAL SYSTEM FLOW GREATER THAN 5 GPM USE PVC TO CONNECT TREE RINGS, DOUBLE OR TRIPLE, AND SIZE PVC APPROPRIATELY. N.T.S. RAIN BIRD TDS-050 WITH BEND TIE DOWN STAKE: RAIN BIRD XFD-CROSS (TYPICAL) BARB X BARB INSERT CROSS: INSTALLED IN VALVE BOX RAIN BIRD XCZ DRIP CONTROL ZONE KIT :IRRIGATION CONTROL VALVE FLOW) PVC SUPPLY HEADER (SIZE BASED ON TOTAL RAIN BIRD MODEL: OPERIND OPERATION INDICATOR RECOMMENDATION XFS-CV SPACING PER RAIN BIRD NON-POTABLE: XFS-CVP DRIPLINE RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL) SUB-SURFACE/ON-SURFACE DRIPLINE: TREE TRUNK RAIN BIRD XF SERIES BLANK TUBING SEE RAIN BIRD DETAIL "XFS-CV FLUSH POINT" FLUSH POINT (TYPICAL) SQUARE CONFIGURATION MINIMUM 1" IN DIAMETER PVC LATERAL PIPE 1"X1"X1/2" SST PVC TEE TWIST LOCK FITTING : TLF-MPT6-0600 RAIN BIRD XFD SERIES BLANK TUBING 1/2" POLYETHYLENE TUBING: FINISH GRADE MULCH BEND (TYPICAL) TIE DOWN STAKE: RAIN BIRD TDS-050 WITH INLINE DRIP EMITTER OUTLET NON-POTABLE: XFS-CVP DRIPLINE (TYPICAL) RAIN BIRD XFS-CV SERIES DRIPLINE ON-SURFACE DRIPLINE: TWIST LOCK FITTING : TLF-TEE 0600 RJKTMGTMGTMGIRRIGATION DETAILS IIR-3 GENERAL NOTES: WITH A SINGLE 1/2" FLUSHING HEADER. PROVIDE WITH END OF MAIN FLUSH POINT VALVE IN VALVE BOX. FOR ALL SHRUB BEDS AND SMALL TURF AREAS, EXTEND DRIP LINE THROUGH THESE AREAS. SUPPLY SHRUB BEDS 10. OR METER BOX. TO PROVIDE THE MINIMUM PRESSURE AT THE FURTHEST STATION. INSTALL THE PRV IN A LARGE DIAMETER TURF AND DELIVERING MINIMUM OF 50 PSIG DOWNSTREAM OF THE PRV. ADJUST THE DISCHARGE PRESSURES OF THE PRV A PRESSURE REGULATOR (PRV) CAPABLE OF RECEIVING THE ACTUAL INLET PRESSURE OBTAINED FROM THE CITY THE MINIMUM PRESSURE AT THE FURTHEST POINT IN THE DRIP SYSTEM OR RZWS IS 40 PSIG. THEREFORE PROVIDE THE BASIS OF DESIGN IS THAT THE MINIMUM PRESSURE AVAILABLE AT EACH STATION VALVE EXCEEDS 50 PSIG. 9. COMPLIANCE REPORTS TO THE OWNER IN THE O & M MANUALS. ALL ELECTRICAL COMPONENTS OF THE SYSTEM. TEST THE SYSTEM TO INSURE COMPLIANCE AND PROVIDE PROVIDE GROUNDING RODS OR SYSTEMS IN ACCORDANCE WITH THE 2016 NATIONAL ELECTRICAL CODE (NEC) FOR 8. ON THE ACTUAL DESIGN PROVIDED BY THE LANDSCAPE IRRIGATION CONTRACTOR. PIPE SIZES INDICATED ARE THE MINIMUM SIZES AND ARE FOR BIDDING PURPOSES ONLY. PROVIDE PIPE SIZES BASED 7. AND OTHER OBSTRUCTIONS. PIPE ROUTING SHOWN IS DIAGRAMMATIC. LOCATE PIPING, VALVES, AND FITTINGS TO AVOID EXISTING TREE ROOTS, 6. OF CENTER FEED SYSTEMS. LOOP ENDS OF ALL DRIPLINE SYSTEMS. DRIP SYSTEMS BASIS OF DESIGN SHALL BE RAINBIRD DRIPLINE. MAXIMIZE FLOW AND PRESSURE THROUGH THE USE 5. BOXES SHALL BE RATED FOR H20 LOADS. DIAMETER, OR OLDCASTLE MODEL 1324 POLYMER VALVE BOX WITH SINGLE PIECE STEEL COVER. ALL VAULTS AND VALVE BOXES SHALL BE NO LESS STRINGENT THAN OLDCASTLE FIBRELYTE MODEL FL08 COMPOSITE 9 INCH HEAVY DUTY, COMMERCIAL GRADE IN CONFORMANCE TO THE CFW STANDARDS, CONTROL VALVE AND SHUT OFF METER VAULTS, BACKFLOW PREVENTER VAULTS, MANUAL SHUT OFF AND CONTROL VALVE BOXES SHALL BE 4. LICENSED LANDSCAPE IRRIGATORS DRAWINGS, PERMITS, INSPECTIONS, ETC, SHALL BE INCLUDED IN THE BID. DESIGNING THE SYSTEM AND COMPLY THEREIN. PROVISIONS FOR TAPPING FEES, PLANS EXAMINATIONS OF THE COORDINATE METERING AND BACKFLOW PREVENTION REQUIREMENTS WITH THE CITY OF DENTON PRIOR TO 3. TO THE PUBLISHED MANUFACTURERS STANDARDS. EVERY VOID TO MAKE THE SLEEVE WATER-TIGHT. DRIP AND RZWS SHALL BE PROVIDED IN STRICT CONFORMANCE PVC SLEEVES WITH 25 YEAR CLEAR SILICONE, A MINIMUM OF 4 INCHES INTO EACH SLEEVE END AND TO FILL 40 RIGID PVC PIPE , ONE INCH DIAMETER NOMINAL PIPE, OR AS REQUIRED BY THE CFW STANDARDS. SEAL ENDS OF LARGER THAN THE PIPE OR TUBING. LOW VOLTAGE CONDUCTORS SHALL BE SLEEVED IN NO LESS THAN SCHEDULE IN CONFORMANCE WITH THE CFW STANDARDS, NO LESS STRINGENT THAN SCHEDULE 80 RIGID PVC TWO SIZES TURFAND SHRUBS. PROVIDE RIGID PVC SLEEVES BETWEEN DRIP STATIONS, BENEATH ROADWAYS, DRIVES AND WALKS PROVIDE ROOT ZONE WATERING SYSTEMS (RZWS) FOR ALL TREES (2 EACH) AND DRIPLINE IRRIGATION FOR ALL 2. IRRIGATION FOR ALL NEW LANDSCAPE PRODUCTS. COORDINATE WITH THE LANDSCAPE DRAWINGS FOR EXACT LOCATION OF ALL COMPONENTS AND PROVIDE WITH THE TXDOT STANDARDS AND REQUIREMENTS. RESIDENTIAL GRADE PRODUCTS ARE NOT PERMITTED. OPERABLE COMMERCIAL GRADE LANDSCAPE IRRIGATION SYSTEM FOR ALL LANDSCAPE PRODUCTS IN CONFORMANCE BASED DESIGN SPECIFICATION, WHERE CONFLICTS EXIST THE MORE STRINGENT SHALL APPLY. PROVIDE A COMPLETE ARCHITECT/ENGINEER AS SHOP DRAWINGS. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THIS PERFORMANCE SYSTEM FUNCTIONAL, SUBMIT THE DRAWINGS TO DENTON FOR APPROVAL BEFORE SUBMITTING TO THE VALVES, PIPE AND FITTINGS, RZWS AND DRIP SYSTEMS INCLUDING EVERY APPURTENANCE REQUIRED TO MAKE THE CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN, INCLUDING EACH AND EVERY COMPONENT OF THE CONTROLS, OF THE SYSTEM INCLUDING BASIC ROUTING, TYPE OF SYSTEM REQUIRED AND SPECIFICATIONS OF COMPONENTS. THE THE SYSTEMS INDICATED ON THESE DRAWINGS ARE A PERFORMANCE BASED DESIGN, PROVIDING THE PARAMETERS 1. - OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE 5 XFCV ON-SURFACE DRIPLINE SLOPED LAYOUT 6 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE TYPICAL ISLAND LAYOUT W/ PVC HEADERS 12"1.33 8".53 1 2 4 3 5 6 8 97 BLACK WIRE x x+ x x+ SLOPE SPACING BOTTOM 1/3 OF NORMAL SPACING TOP 2/3 OF SLOPE xxxxxxxx x x+ x (Feet) XFCV Dripline Maximum Lateral Lengths Inlet Pressure psi 12" Spacing 18" Spacing Nominal Flow (gph)Nominal Flow (gph) 0.6 0.9 0.6 0.9 20 192 136 254 215 30 289 205 402 337 40 350 248 498 416 50 397 281 573 477 60 436 309 637 529 x x+ BURIAL DEPTH DRIP MANIFOLD (Feet) XFS-CV Dripline Maximum Lateral Lengths Inlet Pressure psi 12" Spacing 18" Spacing Nominal Flow (gph)Nominal Flow (gph) 0.6 0.9 0.6 0.9 20 192 136 254 215 30 289 205 402 337 40 350 248 498 416 50 397 281 573 477 60 436 309 637 529 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail02.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017 RJKTMGTMGTMGIRRIGATION 1 LEIT CONTROLLER MODEL LEIT 4000 6 FINISH GRADE 1 2 3 4 6 5 MODEL 30-405 2 HIGH SECURITY STAINLESS STEEL DISC-LOCK 7 NOT TO SCALE CONCRETE BASE USING 90 Lb. (40 kg) BAG OF 5 12" X 18" (30 x 45 cm) CONCRETE CONTROL VALVES. 7 DIRECT BURIAL CONTROL WIRES TO MOUNTING MODEL ENCL 4000 AND INTERNAL CLAMP TO SECURE COLUMN WITH LIGHT ACCESS THROUGH GRID ON TOP 3 HEAVY-DUTY STAINLESS STEEL ENCLOSURE FOR LEIT 4000 AND 4000E 4 GALVANIZED STEEL MOUNTING COLUMN a. MODEL MCOL 4000 32" (81 cm) SHORT b. MODEL MCOL 4000L 48" (124 cm) LONG 6 to 10 FEET HIGH. 5 1" or 1.5" GALVANIZED PIPE VALVE BOX. 9 6" ROUND FROM SENSOR. 13 NORMALLY CLOSED WIRE RAIN SENSOR. 1 "MINI CLIK" WITH HOLE FOR WIRES. 1.5" CAP PART No. 23-053 1" CAP PART No. 23-001 or 2 DIG PLASTIC PIPE CAP FROM SENSOR. 14 COMMON WIRE 11 TO CONTROLLER OR VALVE. 8" DEEP MINIMUM. 6 12" X 12" CONCRETE BASE AND NUT. WITH WASHER, LOCK WASHER 4 (2) #8-32 MACHINE SCREWS FOR SENSOR BRACKET. 3 DRILL TWO 3/16 HOLES IN PIPE SKIT 8 FINISH GRADE. 16 GRAVEL. CONNECTORS. 12 (4) DRY SPLICE 2 LEGEND 7 1" or 1.5" PIPE ELBOW. 15 1"or 1.5" NIPPLE. USE WITH EACH SENSOR. PART NO. 8821-4 10 SKIT ADAPTER 16 15 14 13 12 11 10 NOT TO SCALE WHITE WIREBLACK WIRE RED WIRE 9 6 8 7 5 4 11111111111 3 2 2 5 6 8 10 11 VALVE BOX WITH COVER 12" SIZE FINISH GRADE TOP DIG LEIT 3/4" REMOTE MODEL P52-075 (30 PSI) PVC LATERAL LINE PEA GRAVEL SUMP MINIMUM 3" BRICK SUPPORT AT EACH CORNER 7 10 11 3 4 9 12 SCH 40 TEE PVC SCH 40 90 DEGREE ELL 13 12 1 13 23-004 1" F X 3/4" M MAIN SUPPLY LINE SWIVEL FITTING DIG MODEL CONTROL WIRE TO OTHER VALVE WIRE CONNECTORS CONTROL VALVE ASSEMBLY 3/4" FEMALE NPT COUPLING x SLIP NOT TO SCALE 2 31 MINIMUM2"6 8 5 4 DRY SPLICE CONNECTORS. 4 DIG VALVE MODEL 3/4" 160HE - 075 1" 160HE - 100 7 9 10 11 12 13 10 11 12 13 12 OR 14 GAUGE WIRE. REMOTE CONTROL VALVE FOR LEIT CONTROLLER 1 2 3 5 6 7 8 9 SIZE. VALVE BOX WITH COVER 18" FINISH GRADE TOP. SWIVEL FITTING DIG MODEL 3/4" 23-004, 1" 23-003. PVC SCH 40 MALE ADAPTER. PVC LATERAL LINE. BRICK SUPPORT AT EACH CORNER. PEA GRAVEL SUMP - MINIMUM 3". BACK-UP NPT PVC BALL VALVE. PVC SCH 40 90 DEGREE ELL. SCH 40 TEE. LEGEND 160HE-075 3/4" AND 160HE-100 1" NOT TO SCALE RAIN SENSOR ASSEMBLY (COLUMN MOUNTED) USING SKIT 8821-4 RAIN SENSOR 4000 STAINLESS STEEL ENCLOSURE MODEL ENCL ACCESSIBLE STAINLESS STEEL ENCLOSURE LEIT 4000 AND 4000E WITH LIGHT DRIP ZONE ASSEMBLY FOR LEIT SYSTEM 3/4" PRESET 30 PSI P52-075 DETAILS IIINSTALLED ON EACH FITTING. 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 4. THAT A NEW DRIPLINE ZONE BE CREATED. 3. WHEN ELEVATION CHANGE EXCEEDS 10 FEET IT IS RECOMMENDED MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE SPACING. SEE RAIN BIRD XFD DRIPLINE INSTALLATION GUIDE FOR SUGGESTED OF SLOPE TO BE SPACED GREATER THAN OPTIMAL ROW DISTANCE. ELEVATION. DISTANCE BETWEEN LATERAL ROWS FOR BOTTOM 1/3 BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE NOTES: PVC FLUSH HEADER FOR FLUSH POINT INSTALLATION FLUSH POINT: SEE RAIN BIRD XFCV DETAILS POTABLE: XFCV DRIPLINE RAIN BIRD XF SERIES DRIPLINE (TYPICAL) ON-SURFACE DRIPLINE: PVC SCH 40 TEE OR EL (TYPICAL) PVC SUPPLY HEADER RAIN BIRD XFF-MA FITTING (TYPICAL) BARB X MALE FITTING: FLOW DEMAND) ZONE VALVE KIT (SIZED TO MEET LATERAL PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL 1 2 3 4 5 6 7 DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1. X = DISTANCE BETWEEN ROWS OF DRIP LATERALS AS 2 4 3 5 FP OF SLOPE BOTTOM 1/3 OF SLOPE TOP 2/3 7 6 5 1 4 5 3 2 1 N.T.S. INSTALLED IN VALVE BOX RAIN BIRD XCZ DRIP CONTROL ZONE KIT :IRRIGATION CONTROL VALVE RAIN BIRD MODEL: OPERIND OPERATION INDICATOR FINISH GRADE 2" - 3" DEPTH OF MULCH PAVEMENT AND CURB OF MANIFOLD PIPE SIZE PVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE PVC SUPPLY HEADER RAIN BIRD XFF-ELBOW RAIN BIRD XFF-TEE OR BARB X BARB INSERT TEE OR EL: DETAILS FOR FLUSH POINT INSTALLATION FLUSH POINT (TYPICAL) - SEE RAIN BIRD XFD 2"-4" FROM PERIMETER OF AREA PERIMETER DRIPLINE PIPE TO BE INSTALLED PERIMETER OF AREA NON-POTABLE: XFS-CVP DRIPLINE RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL) SUB-SURFACE/ON-SURFACE DRIPLINE: FLOW DEMAND) ZONE VALVE KIT (SIZED TO MEET LATERAL PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL RAIN BIRD XFF-MA FITTING (TYPICAL) BARB X MALE FITTING: PVC SCH 40 TEE OR EL (TYPICAL) PVC SUPPLY HEADER 2 6 7 1 3 9 8 9 10 7 RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. 6. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION. 5. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE FEET IN CLAY. 4. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE SHOWN IN THE ACCOMPANYING TABLE. 3. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING. PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON 2. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, 1. FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS NOTES: INSET A 1 2 INSET B 12 14 13 4 5 8 INSET A INSET B 6 11 10 11 12 13 14 15 FP 2"-4" FP FP 1 42 2 13 14 1 OP 16 16 15 OP 15 OP15 IR-4 - OF - 1 3 4 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:15:43 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2- COVER.sht9999.9800 ft / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:15:43 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2- COVER.shtProject:Mayhill SouthDefaultModel:DTN18117 CITY OF DENTON, TEXAS LOCATION PROJECT COUNCIL MEMBER.........................SARA BAGHERI COUNCIL MEMBER......................DALTON GREGORY COUNCIL MEMBER..........................JOEY HAWKINS COUNCIL MEMBER................KATHLEEN WAZNEY COUNCIL MEMBER............................KEELY BRIGGS COUNCIL MEMBER.............................KEVIN RODEN MAYOR.....................................................CHRIS WATTS 8000'4000'0 SCALE IN FEET JUNE 2018 TEXAS REGISTERED ENGINEERING FIRM F-2144 CITY MANAGER.................................TODD HILEMAN CITY ENGINEER.................................FRANK G. PAYNE, P.E. ISSUED FOR REVIEW PHASE TWO LANDFILL BUFFER LANDSCAPE DESIGN NOT FOR CONSTRUCTION DATE: THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW UNDER THE NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. AUTHORITY OF MATTHEW L. MILANO TEXAS NO: 3028 JUNE 2018 PLANTING LISTLA-5 PLANTING DETAILSLA-4 LANDSCAPE PLANTING PLANLA-3 LANDSCAPE PLANTING PLANLA-2 ORIENTATION PLANLA-1 SHEET INDEX IR-1 IRRIGATION PLANS IR-2 IRRIGATION PLANS IR-3 IRRIGATION GENERAL NOTES + DETAILS IR-4 IRRIGATION DETAILS II F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- CV-P2-KEYMAP.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:36:37 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2-KEYMAP.sht159.9997 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:36:37 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2-KEYMAP.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNGWSGWSGWS PROPOSED S MAYHILL ROAD LA-2 LA-2 LA-3 LA-3 NOT FOR CONSTRUCTIONDATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THENOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTION.AUTHORITY OF MATTHEW L. MILANOTEXAS NO: 3028JUNE 2018HHEAFEAFMLMLANDSCAPE ARCHITECTUREORIENTATION PLANLA-1 160'80'0 40' SCALE IN FEET PHASE TWO PHASE ONE 1 OF 5 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P2-LANDSCAPE 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:25:57 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 01.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:25:57 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNFL=599.42FL=598.9112"CMPgravelconcrete12"rcpFL=600.68Silted inMail BoxGWSFL=600.04FL=593.11FL=592.9430"RCPBUFFER LIMIT 56' LANDSCAPE BUFFER LIMIT 56' LANDSCAPE TYP. 40' O.C. TYP. 20' O.C. 100'-0" 10' O.C. TYP. TYP. 20' O.C. TYP. 40' O.C. 10' O.C. TYP. 100'-0" SPECIES TREE MLMEAFMLMLA-2 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5 40'20'0 10' SCALE IN FEET LEGEND UNDERSTORY TREE CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3028JUNE 2018MATTHEW L. MILANO7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER. PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES. 6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE 5. DO NOT REMOVE ANY EXISTING TREES. 4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION. 3. REFER TO SHEET LA-4 FOR PLANTING DETAILS. 2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION. 1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE. GENERAL NOTES MATCHLINE BMATCHLINE AMATCHLINE ATO REMAIN EXISTING TREE XX CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CECECECECECECECECECECECECECECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P2-LANDSCAPE 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 05:03:35 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 02.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 05:03:35 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 02.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN24"RCPFL=600.04FL=600.17gravelGWSGWSconcreteBUFFER LIMIT 56' LANDSCAPE BUFFER LIMIT 56' LANDSCAPE TYP. 40' O.C. TYP. 20' O.C. 10' O.C. TYP. 100'-0" 10' O.C. TYP. TYP. 40' O.C. TYP. 20' O.C. 100'-0" SPECIES TREE MLMEAFMLMLA-3 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5 40'20'0 10' SCALE IN FEET LEGEND UNDERSTORY TREE CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018MATCHLINE CMATCHLINE BMATCHLINE C7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER. PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES. 6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE 5. DO NOT REMOVE ANY EXISTING TREES. 4. REFER TO PLANT LIST SHEET LA-4 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION. 3. REFER TO SHEET LA-3 FOR PLANTING DETAILS. 2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION. 1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE. GENERAL NOTES TO REMAIN EXISTING TREE XX CECECECECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P2-PLANT.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:30:11 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANT.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:30:11 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANT.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNMLMEAFMLMLA-4LANDSCAPE ARCHITECT EAF4 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING DETAILSPLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH SURFACE LAYER PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT TREE CENTERED IN HOLE NOTES: 1.TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM COVERAGE. (SEE PLANS FOR TREE LOCATIONS) PLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT PLANTING SOIL MIXTURE EQUALS THREE (3) PARTS EXISTING SOIL AND ON (1) PART FINELY GROUND HARDWOOD MULCH, THOROUGHLY MIXED TREE CENTERED IN HOLE 1/2 INCH DIA. X 36 INCH LONG NAIL STAKES WITH ANGLED TIP AT BOTTOM MULCH TO BE PLACED 3" AWAY FROM TREE TRUNK PLANTING SOIL MIXTURE EQUALS THREE (3) PARTS EXISTING SOIL AND ON (1) PART FINELY GROUND HARDWOOD MULCH, THOROUGHLY MIXED (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL NOTES: WITH THE CITY. INSTALLATION SHALL BE COORDINATED 2. ALL TREE PRUNING AT THE TIME OF SEASON. REMOVED AFTER ONE FULL GROWING ANCHORS AND ARBOR TIE TO BE 1. TEMPORARY TREE WELL, TREE (3) T-POSTS WITH POST CAPS ARBOR TIE TREE STAKING MATERIAL PLANT CROWN AT GRADE 3" MULCH TEMPORARY TREE WELL FINISH GRADE BACKFILL PLANTING PIT WITH PREPARED PLANTING SOIL MIX AS SPECIFIED SCARIFY SURFACE PRIOR TO BACKFILLING TO IMPROVE ROOT PENETRATION TAMP TO PREVENT SETTLEMENT UNDISTURBED SUBGRADE TREE CENTERED IN HOLE NOTES: LOCATIONS) COVERAGE. (SEE PLANS FOR HARDWOOD MULCH BED RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM 1. TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO 1'-0"3" MIN.6" (TYP.) 6" (TYP.)3" MIN.1'-0" 6" (TYP.)3" MIN.1'-0" ON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE ON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE 1 NOT TO SCALELA-4 2 NOT TO SCALELA-4 CANOPY TREE PLANTING AND STAKING DETAIL 3 NOT TO SCALELA-4 UNDERSTORY EVERGREEN TREE PLANTING AND STAKING DETAIL UNDERSTORY MULTI-TRUNK TREE PLANTING AND STAKING DETAIL ON ALL SIDES 1' MIN. CLEARANCE 2 TIMES CONTAINER SIZE T-POSTS F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P2-PLANTLIST.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:22:48 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANTLIST.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:22:48 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANTLIST.shtProject:Mayhill SouthDefaultModel:DTN18117 PLANT SCHEDULE SYMBOL PERCENTAGE SIZE COMMON NAME BOTANICAL NAME CONDITION COMMENTS CANOPY TREE SG #65 CLASS MINIMUM SWEETGUM LIQUIDAMBER STYRACIFLUA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE RC #65 CLASS MINIMUM RED CEDAR JUNIPERUS VIRGINIANA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE AP #65 CLASS MINIMUM AFGHAN PINE PINUS ELDARICA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE BO #65 CLASS MINIMUM BURR OAK QUERCUS MACCROCARPA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE LE #65 CLASS MINIMUM LACEBARK ELM ULUMUS PARVIFOLIA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE PE #65 CLASS MINIMUM PECAN CARYA ILLINOISENSIS CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE RB #65 CLASS MINIMUM RIVER BIRCH BETULA NIGRA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE UNDERSTORY TREE AV #45 CLASS MINIMUM ARBOR VITAE THUGA ACCIDENTAILS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH EP #45 CLASS MINIMUM EAST PALATKA HOLLY ILEX EAST PALATKA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH MR #45 CLASS MINIMUM MEXICAN/ OKLAHOMA REDBUD MEXICANA OR 'OKLAHOMA' CERCIC CANADENSIS VAR. CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH MP #45 CLASS MINIMUM MEXICAN PLUM PRUNUS MEXICANA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH SH #45 CLASS MINIMUM STEVENS HOLLY ILEX NELLI R STEVENS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH PH #45 CLASS MINIMUM POSSUMHAW HOLLY ILEX DECIDUA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH INDICATED IN THE PLANT LIST MAY BE NECESSARY TO PROVIDE THE OTHER MINIMUM CRITERIA INDICATED. CRITERIA REQUIRED. A CONTAINER SIZE LARGER THAN THE MINIMUM SIZE CONTAINER MINIMUM1). ALL SIZES SHOWN FOR ALL PLANTS (SUCH AS CALIPER, CONTAINER SIZE, SPREAD, HEIGHT, BRANCHING HEIGHT, ETC.) ARE THE NOTE: MLMEAFMLMLA-5LANDSCAPE ARCHITECT EAF5 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING LIST7 7 7 4 4 4 3 36 36 22 22 14 14 CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P2-IRRIGATION 01.shtISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 10:57:58 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 01.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 10:57:58 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 01.shtProject:Mayhill SouthDefaultModel:Mail BoxGWSFL=599.42FL=598.9112"CMPgravelconcrete12"rcpFL=600.68Silted in10.75" GAS GATHERINGFL=600.04FL=593.11FL=592.9430"RCPRJKTMGTMGIR-1MATCHLINE AMATCHLINE BMATCHLINE A TMG- OF - 40'20'0 10' SCALE IN FEET IRRIGATIONIRRIGATION PLANS2 TYP. NOTE TO CONTRACTOR PRIOR TO CONSTRUCTION DEPARTMENT FOR APPROVAL PLANS TO PERMIT IRRIGATOR MUST SUBMIT 1 1 2 TYP. NOTE BY SYMBOL " ": GENERAL NOTES: REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1. PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2. AND ROADWAYS PER CITY OF DENTON STANDARDS. MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1. 1 2 TYP. STATION VALVE 2 TYP. 1 1 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P2-IRRIGATION 02.shtISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 11:04:53 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 02.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 11:04:53 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 02.shtProject:Mayhill SouthDefaultModel:GWSGWS24"RCPFL=600.04FL=600.17gravel10.75" GAS GATHERING10.75" GAS GATHERINGconcreteRJKTMGTMGIR-2MATCHLINE CMATCHLINE C TMG- OF - 40'20'0 10' SCALE IN FEETMATCHLINE BIRRIGATIONIRRIGATION PLANSNOTE TO CONTRACTOR PRIOR TO CONSTRUCTION DEPARTMENT FOR APPROVAL PLANS TO PERMIT IRRIGATOR MUST SUBMIT 2 TYP. 1 1 2 TYP. 2 TYP. 2 TYP. NOTE BY SYMBOL " ": GENERAL NOTES: REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1. PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2. AND ROADWAYS PER CITY OF DENTON STANDARDS. MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1.DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN 1 XFS-CV ON-SURFACE DRIPLINE INSERT ADAPTER FOR 1" OR LARGER PVC 3 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE MULTIPLE TREE RING LAYOUT SIDE FED 2 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE QUICK LOOP LAYOUT-MEDIAN ISLAND DOWN SLOPE 2"-4"F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail01.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 13, 2018 - 02:12:20 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\ir-MAY-dt-detail01.dgn0:1 ':" / in.Plot Scale:MicroStation V8 User:Date: Jun. 13, 2018 - 02:12:20 PM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\ir-MAY-dt-detail01.dgnProject:Mayhill SouthSheetModel:N.T.S. 4 3 2 1 1 2 OF DIRECTION. OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE 2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES LOAM, AND FIVE FEET IN CLAY. 1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN NOTES: 3 4 5 6 7 6 5 10 8 7 98 109 N.T.S. FP FP FP 1 2 3 4 5 6 7 8 9 OP 1 2 3 4 5 6 7 89 10 11 10 11 NOTES: 1.FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS 2.SEE XFS-CV TREE RING DOUBLE OR TRIPLE FOR DETAIL OF EACH SET OF RINGS. 3.FOR TOTAL SYSTEM FLOW GREATER THAN 5 GPM USE PVC TO CONNECT TREE RINGS, DOUBLE OR TRIPLE, AND SIZE PVC APPROPRIATELY. N.T.S. RAIN BIRD TDS-050 WITH BEND TIE DOWN STAKE: RAIN BIRD XFD-CROSS (TYPICAL) BARB X BARB INSERT CROSS: INSTALLED IN VALVE BOX RAIN BIRD XCZ DRIP CONTROL ZONE KIT :IRRIGATION CONTROL VALVE FLOW) PVC SUPPLY HEADER (SIZE BASED ON TOTAL RAIN BIRD MODEL: OPERIND OPERATION INDICATOR RECOMMENDATION XFS-CV SPACING PER RAIN BIRD NON-POTABLE: XFS-CVP DRIPLINE RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL) SUB-SURFACE/ON-SURFACE DRIPLINE: TREE TRUNK RAIN BIRD XF SERIES BLANK TUBING SEE RAIN BIRD DETAIL "XFS-CV FLUSH POINT" FLUSH POINT (TYPICAL) SQUARE CONFIGURATION MINIMUM 1" IN DIAMETER PVC LATERAL PIPE 1"X1"X1/2" SST PVC TEE TWIST LOCK FITTING : TLF-MPT6-0600 RAIN BIRD XFD SERIES BLANK TUBING 1/2" POLYETHYLENE TUBING: FINISH GRADE MULCH BEND (TYPICAL) TIE DOWN STAKE: RAIN BIRD TDS-050 WITH INLINE DRIP EMITTER OUTLET NON-POTABLE: XFS-CVP DRIPLINE (TYPICAL) RAIN BIRD XFS-CV SERIES DRIPLINE ON-SURFACE DRIPLINE: TWIST LOCK FITTING : TLF-TEE 0600 GENERAL NOTES: RJKTMGTMGTMGIRRIGATION IR-3 WITH A SINGLE 1/2" FLUSHING HEADER. PROVIDE WITH END OF MAIN FLUSH POINT VALVE IN VALVE BOX. FOR ALL SHRUB BEDS AND SMALL TURF AREAS, EXTEND DRIP LINE THROUGH THESE AREAS. SUPPLY SHRUB BEDS 10. OR METER BOX. TO PROVIDE THE MINIMUM PRESSURE AT THE FURTHEST STATION. INSTALL THE PRV IN A LARGE DIAMETER TURF AND DELIVERING MINIMUM OF 50 PSIG DOWNSTREAM OF THE PRV. ADJUST THE DISCHARGE PRESSURES OF THE PRV A PRESSURE REGULATOR (PRV) CAPABLE OF RECEIVING THE ACTUAL INLET PRESSURE OBTAINED FROM THE CITY THE MINIMUM PRESSURE AT THE FURTHEST POINT IN THE DRIP SYSTEM OR RZWS IS 40 PSIG. THEREFORE PROVIDE THE BASIS OF DESIGN IS THAT THE MINIMUM PRESSURE AVAILABLE AT EACH STATION VALVE EXCEEDS 50 PSIG. 9. COMPLIANCE REPORTS TO THE OWNER IN THE O & M MANUALS. ALL ELECTRICAL COMPONENTS OF THE SYSTEM. TEST THE SYSTEM TO INSURE COMPLIANCE AND PROVIDE PROVIDE GROUNDING RODS OR SYSTEMS IN ACCORDANCE WITH THE 2016 NATIONAL ELECTRICAL CODE (NEC) FOR 8. ON THE ACTUAL DESIGN PROVIDED BY THE LANDSCAPE IRRIGATION CONTRACTOR. PIPE SIZES INDICATED ARE THE MINIMUM SIZES AND ARE FOR BIDDING PURPOSES ONLY. PROVIDE PIPE SIZES BASED 7. AND OTHER OBSTRUCTIONS. PIPE ROUTING SHOWN IS DIAGRAMMATIC. LOCATE PIPING, VALVES, AND FITTINGS TO AVOID EXISTING TREE ROOTS, 6. OF CENTER FEED SYSTEMS. LOOP ENDS OF ALL DRIPLINE SYSTEMS. DRIP SYSTEMS BASIS OF DESIGN SHALL BE RAINBIRD DRIPLINE. MAXIMIZE FLOW AND PRESSURE THROUGH THE USE 5. BOXES SHALL BE RATED FOR H20 LOADS. DIAMETER, OR OLDCASTLE MODEL 1324 POLYMER VALVE BOX WITH SINGLE PIECE STEEL COVER. ALL VAULTS AND VALVE BOXES SHALL BE NO LESS STRINGENT THAN OLDCASTLE FIBRELYTE MODEL FL08 COMPOSITE 9 INCH HEAVY DUTY, COMMERCIAL GRADE IN CONFORMANCE TO THE CFW STANDARDS, CONTROL VALVE AND SHUT OFF METER VAULTS, BACKFLOW PREVENTER VAULTS, MANUAL SHUT OFF AND CONTROL VALVE BOXES SHALL BE 4. LICENSED LANDSCAPE IRRIGATORS DRAWINGS, PERMITS, INSPECTIONS, ETC, SHALL BE INCLUDED IN THE BID. DESIGNING THE SYSTEM AND COMPLY THEREIN. PROVISIONS FOR TAPPING FEES, PLANS EXAMINATIONS OF THE COORDINATE METERING AND BACKFLOW PREVENTION REQUIREMENTS WITH THE CITY OF DENTON PRIOR TO 3. TO THE PUBLISHED MANUFACTURERS STANDARDS. EVERY VOID TO MAKE THE SLEEVE WATER-TIGHT. DRIP AND RZWS SHALL BE PROVIDED IN STRICT CONFORMANCE PVC SLEEVES WITH 25 YEAR CLEAR SILICONE, A MINIMUM OF 4 INCHES INTO EACH SLEEVE END AND TO FILL 40 RIGID PVC PIPE , ONE INCH DIAMETER NOMINAL PIPE, OR AS REQUIRED BY THE CFW STANDARDS. SEAL ENDS OF LARGER THAN THE PIPE OR TUBING. LOW VOLTAGE CONDUCTORS SHALL BE SLEEVED IN NO LESS THAN SCHEDULE IN CONFORMANCE WITH THE CFW STANDARDS, NO LESS STRINGENT THAN SCHEDULE 80 RIGID PVC TWO SIZES TURFAND SHRUBS. PROVIDE RIGID PVC SLEEVES BETWEEN DRIP STATIONS, BENEATH ROADWAYS, DRIVES AND WALKS PROVIDE ROOT ZONE WATERING SYSTEMS (RZWS) FOR ALL TREES (2 EACH) AND DRIPLINE IRRIGATION FOR ALL 2. IRRIGATION FOR ALL NEW LANDSCAPE PRODUCTS. COORDINATE WITH THE LANDSCAPE DRAWINGS FOR EXACT LOCATION OF ALL COMPONENTS AND PROVIDE WITH THE TXDOT STANDARDS AND REQUIREMENTS. RESIDENTIAL GRADE PRODUCTS ARE NOT PERMITTED. OPERABLE COMMERCIAL GRADE LANDSCAPE IRRIGATION SYSTEM FOR ALL LANDSCAPE PRODUCTS IN CONFORMANCE BASED DESIGN SPECIFICATION, WHERE CONFLICTS EXIST THE MORE STRINGENT SHALL APPLY. PROVIDE A COMPLETE ARCHITECT/ENGINEER AS SHOP DRAWINGS. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THIS PERFORMANCE SYSTEM FUNCTIONAL, SUBMIT THE DRAWINGS TO DENTON FOR APPROVAL BEFORE SUBMITTING TO THE VALVES, PIPE AND FITTINGS, RZWS AND DRIP SYSTEMS INCLUDING EVERY APPURTENANCE REQUIRED TO MAKE THE CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN, INCLUDING EACH AND EVERY COMPONENT OF THE CONTROLS, OF THE SYSTEM INCLUDING BASIC ROUTING, TYPE OF SYSTEM REQUIRED AND SPECIFICATIONS OF COMPONENTS. THE THE SYSTEMS INDICATED ON THESE DRAWINGS ARE A PERFORMANCE BASED DESIGN, PROVIDING THE PARAMETERS 1.GENERAL NOTES AND DETAILS- OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN 5 XFCV ON-SURFACE DRIPLINE SLOPED LAYOUT 6 XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE TYPICAL ISLAND LAYOUT W/ PVC HEADERS 12"1.33 8".53 1 2 4 3 5 6 8 97 BLACK WIRE x x+ x x+ SLOPE SPACING BOTTOM 1/3 OF NORMAL SPACING TOP 2/3 OF SLOPE xxxxxxxx x x+ x (Feet) XFCV Dripline Maximum Lateral Lengths Inlet Pressure psi 12" Spacing 18" Spacing Nominal Flow (gph)Nominal Flow (gph) 0.6 0.9 0.6 0.9 20 192 136 254 215 30 289 205 402 337 40 350 248 498 416 50 397 281 573 477 60 436 309 637 529 x x+ BURIAL DEPTH DRIP MANIFOLD (Feet) XFS-CV Dripline Maximum Lateral Lengths Inlet Pressure psi 12" Spacing 18" Spacing Nominal Flow (gph)Nominal Flow (gph) 0.6 0.9 0.6 0.9 20 192 136 254 215 30 289 205 402 337 40 350 248 498 416 50 397 281 573 477 60 436 309 637 529 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail02.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 13, 2018 - 02:15:39 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\ir-MAY-dt-detail02.dgn0:1 ':" / in.Plot Scale:MicroStation V8 User:Date: Jun. 13, 2018 - 02:15:39 PM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\ir-MAY-dt-detail02.dgnProject:Mayhill SouthSheetModel: RJKTMGTMGTMGIRRIGATION 1 LEIT CONTROLLER MODEL LEIT 4000 6 FINISH GRADE 1 2 3 4 6 5 MODEL 30-405 2 HIGH SECURITY STAINLESS STEEL DISC-LOCK 1 7 NOT TO SCALE CONCRETE BASE USING 90 Lb. (40 kg) BAG OF 5 12" X 18" (30 x 45 cm) CONCRETE CONTROL VALVES. 7 DIRECT BURIAL CONTROL WIRES TO MOUNTING MODEL ENCL 4000 AND INTERNAL CLAMP TO SECURE COLUMN WITH LIGHT ACCESS THROUGH GRID ON TOP 3 HEAVY-DUTY STAINLESS STEEL ENCLOSURE FOR LEIT 4000 AND 4000E 4 GALVANIZED STEEL MOUNTING COLUMN a. MODEL MCOL 4000 32" (81 cm) SHORT b. MODEL MCOL 4000L 48" (124 cm) LONG 6 to 10 FEET HIGH. 5 1" or 1.5" GALVANIZED PIPE VALVE BOX. 9 6" ROUND FROM SENSOR. 13 NORMALLY CLOSED WIRE RAIN SENSOR. 1 "MINI CLIK" WITH HOLE FOR WIRES. 1.5" CAP PART No. 23-053 1" CAP PART No. 23-001 or 2 DIG PLASTIC PIPE CAP FROM SENSOR. 14 COMMON WIRE 11 TO CONTROLLER OR VALVE. 8" DEEP MINIMUM. 6 12" X 12" CONCRETE BASE AND NUT. WITH WASHER, LOCK WASHER 4 (2) #8-32 MACHINE SCREWS FOR SENSOR BRACKET. 3 DRILL TWO 3/16 HOLES IN PIPE SKIT 8 FINISH GRADE. 16 GRAVEL. CONNECTORS. 12 (4) DRY SPLICE 2 LEGEND 7 1" or 1.5" PIPE ELBOW. 15 1"or 1.5" NIPPLE. USE WITH EACH SENSOR. PART NO. 8821-4 10 SKIT ADAPTER 16 15 14 13 12 11 10 NOT TO SCALE WHITE WIREBLACK WIRE RED WIRE 9 6 8 7 5 4 11111111111 3 2 2 5 6 8 10 11 VALVE BOX WITH COVER 12" SIZE FINISH GRADE TOP DIG LEIT 3/4" REMOTE MODEL P52-075 (30 PSI) PVC LATERAL LINE PEA GRAVEL SUMP MINIMUM 3" BRICK SUPPORT AT EACH CORNER 7 10 11 3 4 9 12 SCH 40 TEE PVC SCH 40 90 DEGREE ELL 13 12 1 13 23-004 1" F X 3/4" M MAIN SUPPLY LINE SWIVEL FITTING DIG MODEL CONTROL WIRE TO OTHER VALVE WIRE CONNECTORS CONTROL VALVE ASSEMBLY 3/4" FEMALE NPT COUPLING x SLIP NOT TO SCALE 4 2 31 MINIMUM2"6 8 5 4 DRY SPLICE CONNECTORS. 4 DIG VALVE MODEL 3/4" 160HE - 075 1" 160HE - 100 7 9 10 11 12 13 10 11 12 13 12 OR 14 GAUGE WIRE. 3 REMOTE CONTROL VALVE FOR LEIT CONTROLLER 1 2 3 5 6 7 8 9 SIZE. VALVE BOX WITH COVER 18" FINISH GRADE TOP. SWIVEL FITTING DIG MODEL 3/4" 23-004, 1" 23-003. PVC SCH 40 MALE ADAPTER. PVC LATERAL LINE. BRICK SUPPORT AT EACH CORNER. PEA GRAVEL SUMP - MINIMUM 3". BACK-UP NPT PVC BALL VALVE. PVC SCH 40 90 DEGREE ELL. SCH 40 TEE. LEGEND 160HE-075 3/4" AND 160HE-100 1" NOT TO SCALE RAIN SENSOR ASSEMBLY (COLUMN MOUNTED) USING SKIT 8821-4 RAIN SENSOR 4000 STAINLESS STEEL ENCLOSURE MODEL ENCL ACCESSIBLE STAINLESS STEEL ENCLOSURE LEIT 4000 AND 4000E WITH LIGHT DRIP ZONE ASSEMBLY FOR LEIT SYSTEM 3/4" PRESET 30 PSI P52-075 DETAILS IIINSTALLED ON EACH FITTING. 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 4. THAT A NEW DRIPLINE ZONE BE CREATED. 3. WHEN ELEVATION CHANGE EXCEEDS 10 FEET IT IS RECOMMENDED MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE. 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE SPACING. SEE RAIN BIRD XFD DRIPLINE INSTALLATION GUIDE FOR SUGGESTED OF SLOPE TO BE SPACED GREATER THAN OPTIMAL ROW DISTANCE. ELEVATION. DISTANCE BETWEEN LATERAL ROWS FOR BOTTOM 1/3 BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN 1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE NOTES: PVC FLUSH HEADER FOR FLUSH POINT INSTALLATION FLUSH POINT: SEE RAIN BIRD XFCV DETAILS POTABLE: XFCV DRIPLINE RAIN BIRD XF SERIES DRIPLINE (TYPICAL) ON-SURFACE DRIPLINE: PVC SCH 40 TEE OR EL (TYPICAL) PVC SUPPLY HEADER RAIN BIRD XFF-MA FITTING (TYPICAL) BARB X MALE FITTING: FLOW DEMAND) ZONE VALVE KIT (SIZED TO MEET LATERAL PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL 1 2 3 4 5 6 7 DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1. X = DISTANCE BETWEEN ROWS OF DRIP LATERALS AS 2 4 3 5 FP OF SLOPE BOTTOM 1/3 OF SLOPE TOP 2/3 7 6 5 1 4 5 3 2 1 N.T.S. INSTALLED IN VALVE BOX RAIN BIRD XCZ DRIP CONTROL ZONE KIT :IRRIGATION CONTROL VALVE RAIN BIRD MODEL: OPERIND OPERATION INDICATOR FINISH GRADE 2" - 3" DEPTH OF MULCH PAVEMENT AND CURB OF MANIFOLD PIPE SIZE PVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE PVC SUPPLY HEADER RAIN BIRD XFF-ELBOW RAIN BIRD XFF-TEE OR BARB X BARB INSERT TEE OR EL: DETAILS FOR FLUSH POINT INSTALLATION FLUSH POINT (TYPICAL) - SEE RAIN BIRD XFD 2"-4" FROM PERIMETER OF AREA PERIMETER DRIPLINE PIPE TO BE INSTALLED PERIMETER OF AREA NON-POTABLE: XFS-CVP DRIPLINE RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL) SUB-SURFACE/ON-SURFACE DRIPLINE: FLOW DEMAND) ZONE VALVE KIT (SIZED TO MEET LATERAL PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL RAIN BIRD XFF-MA FITTING (TYPICAL) BARB X MALE FITTING: PVC SCH 40 TEE OR EL (TYPICAL) PVC SUPPLY HEADER 2 6 7 1 3 9 8 9 10 7 RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. 6. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION. 5. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE FEET IN CLAY. 4. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE SHOWN IN THE ACCOMPANYING TABLE. 3. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING. PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON 2. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, 1. FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS NOTES: INSET A 1 2 INSET B 12 14 13 4 5 8 INSET A INSET B 6 11 10 11 12 13 14 15 FP 2"-4" FP FP 142 2 13 14 1 OP 16 16 15 OP 15 OP15 IR-4 - OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN