Loading...
2003-262FILE REFERENCE FORM I 2003-262 I X Additional File Exists Additional File Contains Records Not Public, According to the Public Records Act Other FILE(S) Date Initial Amended by Ordinance No. 2004-260 09/21/04 Amended by Ordinance No. 2004-386 12/07/04 ORDINANCE NO. 2003-~. ~,,~ AN ORDINANCE OF THE CITY OF DENTON, TEXAS AMENDING THE SCHEDULE OF RATES CONTAINED IN ORDINANCE NO. 2002-267 FOR ELECTRIC SERVICE; INCLUDING ALL PROVISIONS OF ORDINANCE NO. 2002-331 AS A PART OF THE RATE ORDINANCE (SCHEDULE EP); PROVIDING FOR A REPEALER; PROVIDING FOR A SEVERABILITY CLAUSE; AND PROVIDING FOR AN EFFECTIVE DATE. THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS: ~qF,(2TIONI 1 That the Schedule of Rates for electrical services as provided for in Chapter 26 of the City of Denton Code of Ordinances, is amended to read as follows: ELECTRIC RATE SCHEDULES PAGE R1 Residential Service Rate 2 R2 Residential Service Rate 4 TR Residential Time of Use Rate 6 GSL General Service Large 8 GSS General Service Small 11 TGS General Service Time of Use Rate 14 WK Weekend Rate 18 G1 Local Government Light'mg & Power Service Rate 21 [City, County, Independent School District] LS Street Lighting 23 LT Traffic Lighting 25 LO Other Lighting 26 DD Dusk-to-Dawn Lighting [Security Light] 27 DDL Downtown Decorative Lighting 29 DGL Decorative Ground Lighting 30 T1 Temporary Service Schedule 32 P1 Intermptible Primary Service 34 ES Standby, Supplementary and Maintenance Service 36 AF Athletic Field 40 IDR Industrial Development Rate 42 EP EnergySave Program 43 MTR Premium-Efficiency Motor Rebate 47 UPS Uninterruptible Power Supply 49 ECA Energy Cost Adjustment 51 Special Facilities Rider 52 Discount Rider for State Universities and Colleges 53 SCHEDULE R1 R F,,qlDFJqTIAI, ,qF, l~ VTCI~. R ATI~ (Effective 10/01/03) APPI ,TC ATICINT Applicable to all electric service used for residential purposes in a single family dwelling or an individually metered apartment; supplied at one point of delivery and measured through one meter where usage is not in excess of 700 l(Wlq per 30-day month during the billing months of May through October. I f u sage in any such month exceeds 700 KWH, billing will be rendered that month under Rate Schedule R2 and thereafter for a period extending through the 12 billing months of the next year ending with the October billing. Annually, in November, the customer may again qualify for the R1 rate provided that consumption has not exceeded 700 KWH per 30-day month during the previous six summer months. Where individual dwelling units are being served through the same meter and the KWH in the billing months of May through October exceed 700 KWH times the number of dwelling units, the billing for that month and thereafter will be rendered under Rate Schedule R2. NET MONTHT (1) Facility Charge $6.70 / 30 days (2) Energy Charge 3.85¢ / KWH (3) Energy Cost Adjustment Schedule ECA M1N1MI IM FIll J,1NG Facility Charge TYPF, OF RF, RVICF, The City will supply single-phase service at any standard voltages available from the City's distribution system through one standard transformation. Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days f~om date of issuance. 2 ~P~TAT, FACII ,T'I'TI~,~ All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PRORATION OF I ITII ,TTY [III J Billing for the Facility charge shall be based on twelve (12) billings annually and prorated for longer or shorter billing periods using the following formula. Formula: Aa~11al dayg in reading peHnd x Customer Facility Charge 30 days RNFRR GY CI-IA R GI~ Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH rate F,,NTR, R G¥ CO,qT ADH I,qTM~NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. SCHEDULE 112 RF,~qlDF, NITIAI. ~qF, R VTC,~, R ATF, (Effective 10/01/03) APPT JCATIC)NT Applicable to any customer for all electric service used for residential purposes in an individual private dwelling or an individually metered apartment, supplied at one point of delivery and measured through one meter. Also applicable to any customer heating with electric energy, resistance or heat pump. Not applicable to resale service in any event, nor to temporary, standby, or supplementary service except in conjunction with the applicable rider. NF.T MONTI-II,Y R AT1R, (1) Facility Charge Single-Phase Three-Phase (2) Energy Charge First 1,000 KWH Additional KWH First 3,000 KWH Additional KWH (3) Energy Cost Adjustment MINIM[ IM BII J JNG Single-Phase Three-Phase WINTRR ,ql IMlk~,R Billing months of NOV. through APRIL $ 7.73 / 30 days $15.45 / 30 days 4.34¢ / KWH 3.94¢ / KWH Schedule ECA Facility Charge Facihty Charge Billing months of MAY through OCT. $ 7.73 / 30 days $15.45 / 30 days 5.61¢ / KWH 6.21¢/KWH Schedule ECA TYP~. oF The City will supply single-phase service (or three-phase service if available at the point of delivery) a t sixty (60) cycles a nd a t a ny standard voltages available from t he City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required in advance. Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. ,qPRCTAT. FACII JTYl~.,q All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PROR ATICjNT C)F I IT[[ ,TT¥ RTl' ,1 ,g Billing for the Facility charge shall be based on twelve (12) billings annually and prorated for longer or shorter billing periods using the following formula: Formula: Aehml daya in reading period 30 days x Customer Facility Charge I~NFI~R G¥ CFIAR GF. Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block RNFR. RG¥ (]O~qT AD[[ I.qTM1RNT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. SCHEDULE TR Rlq.,qlDENTTAT, TTMI~ OF ! l,qlq, R ATE (Effective 10/01/03) APPl JCATIONI Applicable to any customer for all electric service used for residential purposes in an individual private dwelling or an individually metered apartment, supplied at one point of delivery and measured through one meter. Customers applying for the TR rate must remain on this rate for twelve (12) continuous billing periods. Not applicable to resale service in any event, nor to temporary, standby, or supplementary service except in conjunction with the applicable rider. NF.T MONTHI ~¥ R ATR (1) Facility Charge Single-Phase Three-Phase (2) Energy Charge On-Peak Hours Off-Peak Hours (3) Energy Cost Adjustment $15.45 / 30 days $20.60 / 30 days 25.55¢ / KWH 1.41¢ / KWH Schedule ECA MINIM[ IM glll,l .lNG Facility Charge TYP~ OF ,qF, R VI(~I~ Single-phase or three-phase at sixty (60) cycles at secondary distribution voltage. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may first be required. DF. F1NITIC)N OF CIN-PF, AK HOT IRS The Ci~s on-peak hours, for the purpose of this rate schedule, are designated as being from 2:00 P.M. to 7:00 P.M. each Monday through Friday, starting on June 1 and continuing through September 30 each year. The City's on-peak hours may be changed from time to time and the customer will be notified twelve (12) months before such changes become effective. DF, FINqTIONI ~f OFF-P1R, AK ROI IR,q The Ci~s off-pe~ ho~s, for ~e p~ose offs rate schedule, shill be all ho~s not desi~ated ~ on-pe~ ho~s. RP~,CTAT, FAC~ ~l se~cos w~ch roqfflro spoci~ facilities ~ order to meet customer's se~ce requirements shall be provided subject to ~e Special Facilities ~der. PRORATION OF 1 ~H,~Y RH J ,~ Billing for ~e F acili~ C h~ge s bM1 b e b ~ed o n twelve (12) b ill~gs a~uMly and prorated for longer or shoner periods us~g ~e follow~g fo~ula: Achml da? in reading pe6nd x Customer Facili~ Ch~ge 30 days F~RGY CHARGE Bill~g for ~e ener~ ch~ge shM1 be b~ed on actual K~ coemption d~g ~e bill~g period. Fo~ula: K~ in rate block x ~te per K~ ~ rate block A chmge per K~ of ener~ t~en for ~el cost cflculated ~ aecord~ee wi~ Schedule ECA. PA~T Bills me due when rendered, ~d become past due if not paid wit~ fi~een (15) cflend~ days ~om date of issu~ce. SCHEDULE GSL ~TI~JNFRR AT, ~qE, R VfCF, T ,AR Ctl~ (Effective 10/01/03) APPT JCATION The GSL Rate is applicable to any commercial or industrial customer having a minimum actual demand of 250 KVA or 225 KW for all electric service supplied at one point of delivery and measured through one meter. Customers with an average actual demand equal to or greater than 200 KVA or 180 KW during the previous twelve month period may be allowed service under this rate, subject to the minimum billing provision. Customers other than commercial and industrial may be allowed service under tins rate, subject to the minimum billing provision. Customers who elect to discontinue service under this rate are ineligible for service under this rate for twelve months. This rate is not applicable to resale service in any event, nor to temporary, standby, or supplementary service except in conjunction with the applicable rider. NF, T MONTHI ,Y R ATR (1) (2) (3) (4) Facility Charge Demand Charge Energy Charge (GL1) $60.60 / 30 days $8.64 / KVA (Minimum of 250 KVA billed) 1.41¢ / KWH Energy Cost Adjustment: Schedule ECA MINIMI IM Rll J,TN'G An amount equal to the facility charge, plus a demand charge billed at the above KVA rate, where demand is determined by winchever of the following methods yields the greatest result numerically: (1) the actual monthly KVA demand; (2) 250 KVA; or (3) seventy percent (70%) of the maximum monthly KW/KVA actual demand for any month during the previous billing months of May through October in the twelve months ending with the current month. Secondary or primary service available to commercial and industrial customers. Primary service is rendered at one point on the customer's premises at a nominal voltage of 13,200 volts. PRTMAR¥ ~F, RVI'O.F, DI~O.C)T TNT Customers who own, operate, and maintain all facilities necessary to receive three phase primary voltage service and all transformation facilities required for conversion to utilization voltage shall receive a discount of 0.3C/KWH (GL3). Primary service customers utilizing City owned and operated facility and transformation equipment necessary to receive primary voltage service shall receive a discount of 0.1C/KWH (GL2). The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage. P A YMF. NT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. DRTRR1M'INIATIONI OR DRMAND The demand shall be determined by the KVA supplied during the fifteen (15)-minute period of maximum use during the current month as determined by City's demand meter, but shall not be less than 70% of the highest monthly KW/KVA actual demand determined during the billing months of May through October in the twelve (12) months immediately preceding the current month. If the current monthly demand is less than 250 KVA, and 70% of the actual demand determined during the previous months of May through October is less than either 250 KVA or 225 KW, a minimum of 250 KVA demand will be billed for the month. In all cases, 250 KVA is the minimum demand billable under rate GSL. SPRCIAI, FAC~Il ,ITIE~S All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PROR ATTCINI OF I Fl'Il JTY gll J ,S (a) Billing for the Facility charge s hall b e based o n twelve (12) billings annually a nd prorated for longer or sho~ter billing periods using the following formula: Formula: Actual da? in reading period 30 days x Customer Facility Charge (b) Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Formula: Aehml dawq in reading peHnd ~ x KVA Demand x Rate 30 days RNIF, R GY CHARGF, Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH Rate F~NrF, RGY COST ADII T~qTMF, NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. l0 SCHEDULE GSS CtI~NT1RR AT. ~qF, R VTCF( .qk4AT,T, (Effective 10/01/03) ApPI ,TC ATIONI The GSS rate is applicable to any commercial or industrial customer having a maximum demand less than 225 KW for all electric service supplied at one point of delivery and measured through one meter. Not applicable to resale service in any event, nor to temporary, standby, or supplementary service except in conjunction with the applicable rider. NE.T MONTHI.Y r ATF, ( 1 ) Facility Charge Single Phase Three Phase (2) Demand Charge (3) $15.15 /30 days $20.20 / 30 days $8.00 / KW (First 20 KW not Billed) Energy Charge (GS 1 ) Customer with 20 KW or below: Block 1 - First 2,500 KWH Block 2 - All Additional KWH 6.75¢ / KWH 3.0O¢ / KWH Customer above 20 KW: Block 1 - First 2,500 KWH Block 2 - Next 3,500 + B2T* KWH Block 3 - All Additional KWH 6.75¢ / KWH 3.00¢ / KWH 2.65¢ / KWH * The Block 2 Threshold (B2T) establishes the upper threshold for the Block 2 billing rate above 6,000 KWH as a fimction of demand, and is determined by the following formula: (4) B2T KWH = [(Actual KW Demand - 20) x 190] No customer shall be billed for KWH not actually consumed. Energy Cost Adjustment Current ECA Schedule 11 An amount equal to the facility charge plus the greater off (1) the actual monthly KW demand charge, or (2) seventy percent (70%) of the maximum monthly actual demand charge for any month during the previous billing months of May through October in the twelve (12) months ending with the current month. Secondary service available to commercial and industrial customers. The City will supply single-phase service (or three-phase service if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from t he City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may first be required. PRIMARY .qF, RVIO. F, D[q(21~l ]NT Customers who own, operate, and maintain all facilities necessary to receive three-phase primary voltage service and all transformation facilities required for conversion to utilization voltage shall receive a discount of 0.3C/KWH (GS3). Primary service customers utilizing City owned and operated facility and transformation equipment necessary to receive primary voltage service shall receive a discount of 0.1C/KWH (GS2). The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage. pAS~4'ENT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. DF, TF, RMINIATIOlXl 01~ DRMANT) The demand shall be determined by the KW supplied during the fifteen (15)-minute period of maximum use during the current month as determined by City's demand meter, but shall not be less than 70% of the highest monthly actual demand determined during the billing months of May through October in the twelve (12) months immediately preceding the current month. Billing demand shall be based o n a n adjusted K W demand which i s t he highest o f t he a ctual.m onthly demand, less 20 KW or 70% of the maximum monthly actual demand during the preceding months of May through October, less 20 KW. In no case, shall billed demand be less than 0 KW. In cases where the connected load is constant, the City may, at its option, estimate the KW demand. For neon signs, one volt ampere shall be considered the equivalent of 3/4 watt. 12 SPECIAl-, I~'A C]T All services which require special facilities in order to meet ¢.stomer's service requirements shall be provided subject to the Special Facilities Rider. PRCIR ATT(IN OF I ITll JTY RII J,S (a) Billing for the Facility charge s hall b e based o n twelve (12) billings annually a nd prorated for longer or shorter periods using the following formula: Formula: Actual dayg in reading perind 30 days x Customer Facility Charge (b) Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Formula: Actual cla?q in reading periocl 30 days x Adjusted KW Demand x Rate Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block F, NII~,RG¥ COST AD.II ISTMF, NIT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 13 SCHEDULE TGS GF, N'~,R A T, R~RVTC~ TBVI~. OF Ting, RATE (Effective 10/01/03) A PPT ,TC A TTON Applicable to any customer having a minimum demand of 250 KVA for all electric service supplied at one point of delivery and measured through one meter, with the City providing all facilities necessary to receive primary voltage service. Supplementary service will b e available subject to the applicable rider. Not applicable to resale or temporary service. Customers electing tlxis rate must remain on this rate for a minimum of twelve (12) continuous billing months. NIE, T MONTI-II .¥ R ATR (1) (2) (3) (4) (S) Facility Charge On-Peak Demand Charge Off-Peak (System) Demand Energy Charge Energy Cost Adjustment: $70.70 / 30 days $10.98 / KVA On-Peak Demand $ 2.16 / KVA System Demand Charge 0.51¢ / KWH Per Schedule ECA MINIM] ]M R'I~ J ,lNG The minimum monthly bill shall be the sum of the Customer Facility Charge, the Off-Peak Demand Charge, and the On-Peak Demand Charge. The October through May demand charge shall be the measured system demand, plus not less than 100% of the actual maximum monthly on-peak demand for any month during the months of June through September in the twelve (12) months mediately preceding the current month. TYP]~ OF ,~F,R VIC, F, Secondary or primary service available to commercial and industrial customers. Primary service is rendered at one point on the customer's premises at a nominal voltage of 13,200 volts. The City will supply single-phase service (or three-phase service if available at the point of delivery) a t sixty (60) cycles and at a ny standard voltages available from t he City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. 14 pRTMAR¥ ~qF. RvlCF, T')[.~COI YNT'T' Customers who own, operate and maintain all facilities necessary to receive three-phase primary voltage service and all transformation facilities required for conversion to utilization volfage shall receive a discount of 0.3C/KWH (TG5 and TG6). If primary service is provided and the City owns and operates all facilities and transformation equipment necessary to receive primary voltage service, a discount of 0.1C/KWH will be applied to the customer's bill (TG3 and TG4). The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage, at the City's option. DEFTNTT'TON OF ONT-PF. AK T-IOI 1R.q The City's on-peak hours, for the purpose of this rate schedule, are designated as being f~om 2:00 P.M. to 7:00 P.M. each Monday through Friday, for the months of June through September. The City's on-peak hours may be changed from time to time and the customer will be notified twelve (12) months before such changes become effective. DF. FINITTONI OF OFF-PEAK HOT JR R The City's system (off-peak) hours, for the purpose o fthis rate schedule, shall b e all hours not designated as on-peak hours. DETRRMINATICIN OF ON-PEAK D~MAND The on-peak demand shall be determined by the KVA actual demand supplied during the fifteen (15) minute period of maximum use each month during on-peak hours as recorded by the City's demand meter, but not less than one hundred percent (100%) of the actual maximum on-peak demand similarly determined during the billing months of June through September in the twelve (12) months immediately preceding the current month. DF. TERMIN'ATTC}N OF OFF-PF,,AK (SYSTEM). DEMAND The off-peak demand shall be determined by the maximum KVA actual demand supplied during the fifteen (15) minute period of maximum use during off-peak hours each month as recorded by the City's demand meter. The off-peak demand will be billed every month. DF. TERMINATION OF DEMAND RIIJ.1NG FOR CII,qTOM~RR Wrl'I4 NO PEAK DEMAND Iq'TRTORY DI JRTNG OFF-PEAK MONTHS If the customer is new or does not have a history of on-peak use for June through September, and elects to come on the TGS rate, the customer's billed demand shall be the off-peak demand billed at the GSL demand rate. The off-peak demand will be billed every month at the GSL rate until the customer establishes a separate on-peak and off-peak demand during an on-peak month. At this time, both on-peak and off-peak demand will then begin billing at the TGS rate. 15 ,qT FppT .I~MF. NTTAT, POWF, R RIDER Customers requesting standby or supplementary power shall be allowed service under this rate schedule; however, the determination of off-peak demand shall be adjusted to read: The off-peak demand shall be the sum of the maximum KVA demand supplied during the fifteen (15) minute period of maximum use as recorded by the City's demand meter plus the KVA nameplate rating(s) of the customer's generator(s). In the event the customer's generator(s) is/are off-line at the time of the establishment of the maximum off-peak demand, the KVA nameplate rating of the generator(s) unavailable for service shall be removed fi.om the determination of the off-peak demand. .qpF,,C~IA 1, ~'AC~IT ,TTIF..q All services which require special facilities in order to meet the customer's service requirements shall be provided subject to the Special Facilities Rider. PR OR A TTIDNI/DF ! Fl'II ,IT¥ girl' ,l ,.q (a) Billing for the Facility Charge shall be based on twelve (12) billings annually and prorated for longer or shorter periods using the following formula: Antnal daw in readln~ nerlnd - - - x Customer Facility Charge 30 days Co) Billing for demand shall be calculated on a thirty (30)-day-per-month basis and prorated for longer or shorter billing periods using the following formula: Aehlal daw in reading period ' x KVA Billed Demand x Rate 30 days F~NII~,R GY CI-I AR GF, Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH Rate FJ'q~R GY CC),qT ADII LqTMF, NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 3.6 PAYMENT Bills arc duc when r~nd~rcd, and become past duc if not paid within fifteen (15) calendar days t~om date of issuance. l? APP[ JCATION SCHEDULE WK WR, FJ(F, ND R ATE (EFFECTIVE i0/01/03 Applicable to any commemial and industrial user whose maximum demand load occurs during the period fi.om Thursday at 12 midnight through Sunday at 12 midnight and does not experience a demand load during the per/od fi.om Sunday 12 midrfight through Thursday 12 midnight that exceeds 80% of the maximum demand load. Customers who violate the 80% requirement more than four (4) times during the month, or more than twice on the same day of the week, during the months of June through September, are ineligible for service under this rate for twelve (12) months. Not applicable to resale service in any event, nor to temporary, standby or supplementary service except in conjunction with applicable rider. NI~.T MONTI-ll .Y R ATF, 0) (2) (3) (4) Facility Charge Single-Phase Three-Phase Demand Charge Energy Charge (GS 1 ) Customer with 20 KW or below: Block 1 - First 2,500 KWH Block 2 - All Additional KWH Customer above 20 KW: Block 1 - First 2,500 KWH Block 2 - Next 3,500 + B2T* KWH Block 3 - All Additional KWH $20.00 / 30 days $25.00 / 30 days $ 6.40 / KW (First 20 KW not Billed) 6.75¢ / KWH 3.00¢ / KWH 6.75¢ / KWH 3.00¢ / KWH 2.65¢ / KWH * The Block 2 Threshold (B2T) establishes the upper threshold for the Block 2 billing rate above 6,000 KWH as a function of demand, and is determined by the following formula: B2T KWH = [(Actual KW Demand - 20) x 190] No customer shall be billed for KWH not actually consumed. Energy Cost Adjustment Per Schedule ECA 18 An mount equal to the demand charge as calculated below plus $20.00/month for single -phase service or $25.00/month for three-phase service, per thirty (30) day billing. TYPlq OF ,qF, RVICF, The City will supply single-phase service (or three-phase service if available at the point of delivery) a t sixty (60) cycles a nd a t a ny standard voltages available from t he City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. PAYMF, NT Bills are due when rendered and become past due if not paid within fit~een (15) calendar days from date of issuance. DETERMINTATIONT OF DI~.MAND The demand shall be determined by the KW supplied during the fifteen (15) m'mute period of maximum use during the current month as determined by the City's demand meter. Billing shall be based on an adjusted KW demand, which is the actual demand less 20 KW. The adjusted KW demand will subsequently be used for billing the demand portion of the utility bill. In no case, shall billed demand be less than 0 KW. SPECIAl, FACII ,lTHq,q All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PR OR ATTON OF I ITII JTY RTI,I ,R Billing for customer facility charge and demand shall be calculated on a thirty (30) day basis and prorated for longer or shorter billing periods using the following formula: (a) Billing - Customer Facility Charge shall be based on twelve (12) billings annually. Formula: Achml dayg in reading period 30 days x Customer Facility Charge 19 Billing - Demand Charge shall be based on twelve (12) billings annually. Formula: AchTal days in reading period 30 days x Adjusted KW Demand x Rate Billing for the energy charge shall be based on actual KWH consumption during the billing per/od. Formula: KWH in rate block x Rate per KWH in rate block ENE. R Gy COST ADH I,qTM]q. NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 20 SCHEDULE G1 T,OC. AI, C~OVD,,RNTMRNT l JCtHTTNC~ .~-. pOWg. R ,qRI~VTCR RATR [CITY; COT INTY; AND TNDEPENDENT ~CHOOI, DI,RTrTCT] (Effective 10/01/03) APPl ,lC ATION Applicable to any local City, County or School District for all electric service supplied at one point of delivery and measured through one meter. Not applicable to resale service in any event, nor to temporary, standby or supplementary service except in conjunction with applicable rider. NRT MC}NTI-II.Y l~ ATR (1) Facility Charge Single-Phase $15.15 / 30 days Three-Phase $20.20 / 30 days (2) Demand Charge $6.31 / KW (3) Energy Charge 3.03¢ / KWH (4) Energy Cost Adjustment Current ECA Schedule MTNTTMI ITVI [tll.T .lNG An mount equal to the demand charge as calculated below, but not less than fifty percent (50%) of the maximum monthly demand charge for any month during the previous billing months of May through October in the twelve (12) months ending with the current month, plus the applicable facility charge per thirty (30) day billing period. TYPR OF ~qRRVICR The City will supply single-phase service (or three-phase service if available at the point of delivery) a t sixty (60) cycles a nd a t a ny standard voltages available from t he City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. PAYMENT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days fi:om date of issuance. 23. D~,TFRMINATION OR DEMAND The demand shall be determined by the KW supplied during the fit~een (15)-minute period of maximum use during the current month as determined by City's demand meter, but not less than 50% of the highest monthly actual demand determined during the billing months of May through October in the twelve (12) months immediately preceding the current month. SPECIAL RACII ,TTTF,,,q All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PROR ATIC}NI O1~ 1 FIR ,1TV' RII J ,R (a) Billing for the Facility charge s hall b e based o n twelve (12) b filings annually and prorated for longer or shorter billing periods using the following formula: Formula: Acmnl daya in reading period 30 days x Customer Facility Charge Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Formula: Ach]aT da.va in reading period 30 days x KW Billed Demand x Rate F, NF.R GY CRA R Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH Rate ENERGY COST ADH I.qTMI~NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 22 SCHEDULE LS .qTR F,F,T T ,TC, HTING (Effective 10/01/03) APPl JCATION Applicable to all street lighting owned and maintained by thc City of Denton. NET M~NTHT .¥ R ATIR (1) Facility Charge (2) F, nergy Cogt Adju~lment See table Current ECA × Monthly Bulb Wattage Factor Facility Charge 1qnlh Wall-age Factor LSA 100 W Sodium Vapor LSB 250 W Sodium Vapor LSC 400 W Sodium Vapor $ 4.90 / 30 Days 48 KWH $ 6.95 / 30 Days 105 KWH $ 8.75 / 30 Days 159 KWH LMA 175 W Mercury Vapor $5.65 / 30 Days 70KWH LMB 250WMereuryVapor $6.70 / 30 Days 98KWH LMC 400 W Mercury Vapor $8.50 / 30 Days 153KWH LMD 1,000 W Mercury Vapor $15.45 / 30 Days/380 KWH TYPF. OF RFRVIC[~ The City will supply single-phase service (or three-phase service if available at the point of delivery) a t sixty (60) cycles a nd a t a ny standard voltages available from t he C it,rs distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may first be required. PAYMF. NT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. 23 PR OR ATION OF 1FF1]' JTY Pill ,! ,~ a) Billing for the Facility Charge shall be based on twelve (12) billings armually 'and prorated for longer or shorter periods using the following formula: Actual dav,~ in re~din~ nerlnd ~ -' x #oflightspertype x 30 days Customer Facilities Charge I~NII~RG¥ cO~qT AD J1 IRTMENIT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 24 SCHEDULE LT TR AFFTC l ,IGHTING (Effective 10/01/03) APPl ,TC ATION Applicable t o State and Local Government agencies t hat operate and maintain t heir own traffic signals. NI~T MONTHI,Y R ATE All KWH 5.30¢ / KWH TYPE OF ~qF~RVICE At the City's available secondary voltage and phase. Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. MA1NTF~NANCIq CHAllGF, Maintenance expenses billed at cost. ,qPECIAI, FACII JTl~,~q AIl services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. FNFR G¥ CI-IAR GE Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH × KWH Rate F, NFRG¥ tqO.qT ADJI I,qTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 25 SCHEDULE LO OTHE, R l' .IGHT1NIG (Effective 10/01/03) IDA APPl JCATION Applicable to State and Local Government agencies that install and maintain their own street lights, other than the City of Denton. T LS 1 250 W Sodium Vapor LS2 400 W Sodium Vapor LM1 400 W Mercury Vapor LM2 1,000 W Mercury Vapor APPI ,lC ATION Applicable to other unmetered lighting services. N!FT MONFFI-II .¥ RATR Total Watt~ 1,000 TYPF, OF ~qFRVICF, At the City's available secondary voltage and phase. PAYMFiNT Nq~,T MONTHLY RATI~ 5.30¢ / KWH 5.30¢ / KWH 5.30¢ / KWH 5.30¢ / KWH x Hours used per Month x KWH Rate BULB WATTAGE FACTOR 105 KWH 159 KWH 153 KWH 380 KWH Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. M A IN!TI~Jq'A N!CI~ CH A R G'0'. Maintenance expenses billed at cost. SPF, CIAI, FAC1T,1T1F,,R All services which require special facilities in order to meet customer's service requirements shill be provided subject to the Special Facihties Rider. F, NF, RGY COST ADH IRTMF;NT A charge per KWH of energy taken for fuel cost calculated in accord with Schedule ECA. SCHEDULE DD DT T~qT( Tl~ DAWN T,TGHTTN~t [SECURITY LIGHT] ~ffective 10/01/03) APPT ,ICATT~N Applicable to ~y customer witch ~c a rca s c~cd b y thc C i~s e locke d is~bution systcm for outdoor ~ca li~t~g when such li~ting facilities ~c operated as ~ extension og ~ Ci~s dis~bution system. krl~,T MC)NTI-~f,¥ R ATE (1) Fanillty Charge See table (2) Pnex~my Cn~t A~,mtment Current ECA x Monthly Bulb Wattage Factor Facility Charge Fh,lh Waft-age Factor DSA 100 W Sodium Vapor $7.75 / 30 Days 48 KWH DSB 250 W Sodium Vapor $10.05 / 30 Days 105 KWH DSC 400 W Sodium Vapor $12.35 / 30 Days 159 KWH DHA 250 W Metal Halide $12.05 / 30 Days 105 KWH DHB 400 W Metal Halide $14.35 / 30 Days 159 KWH Restricted 10/1/97: DMA 175 W Mercury Vapor DMB 250 W Mercury Vapor DMC 400 W Mercury Vapor $6.45 / 30 Days $7.50 / 30 Days $8.35 / 30 Days 70 KWH 98 KWH 153 KWH The City shall furnish, install, maintain and deliver electric service to automatically controlled, mercury or sodium vapor 1 ighting fixtures conforming t o t he C i~s standards a nd subject t o i ts published roles and regulations. Where necessary for proper illumination or where existing poles are inadequate, the City will install or cause to be installed, one (1) pole for each installed light, at a distance not to exceed eighty (80) feet from said existing lines, at no charge to the customer. Each additional pole span shall not exceed a span spacing of one hundred (100') feet. Additional poles required to install a light in a customer's specifically desired location, and not having a light installed on same, shall bear the cost. 27 PAYMENT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days from date of issuance. TF, RM OF CIDNTR ACT A two (2) year contract shall be agreed to and signed by each customer desiring Dusk-to-Dawn Lighting Service authorizing fixed monthly charges, which may be reviewed annually, and to be applied to the monthly municipal utilities bill. In the event that a customer desired the removal of the trait or discontinuance of the service prior to completion of two (2) years, the remainder of the contract period shall become due and payable. After the end of the initial two (2) year contract, service shall continue on a month- to-month basis and may be canceled by either party upon thirty (30) days notice. ~PFI~TAI. FACII.TTTF..,~ All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to the Special Facilities Rider. PROR ATTiDN OF I ri'II,lTV glT,l ,,q Billing for the Facility charge shall be based on twelve (12) billings annually and prorated for longer or shorter billing periods using the following formula: Formula: Aehml daya in reading period 30 days x Customer Facility Charge EN1E. RG¥ C{),qT ADII IRTMF. NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 28 APPT JC. ATTON SCHEDULE DDL DOWNTOWN FI'F.(2Og A TUv'D'. T,TCtHTINCt (Effective 10/01/03) Applicable to any customer on the perimeter of the square served by the City's electric distribution system for outdoor area lighting when such lighting facilities are operated as an extension of the City's distribution system. MONTIqI,Y R ATF, Facility Charge $3.85 / 30 Days (2) Energy Cost Adjustment Current ECA x Monthly Bulb Wattage Factor, based on 415 KWH per Customer TYPE OF RF. RVICF. The City shall furnish, install, maintain and deliver electric service to automatically controlled lighting fixtures conforming to the City's standards and subject to its published rules and regulations. The service is provided between dusk and midnight. PAYM~,NT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days fi:om date of issuance. ,qPF, C. IAI, FACII ,ITI~,R All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to Special Facilities Rider. PR OR A TION OF T ITII,ITY RII J ,g Billing for the Facility Charge s hall b e based o n twelve (12) billings annually and prorated for longer or shorter billing periods using the following formula: Formula: Aenml day,q in reading perlnd 30 days x Facility Charge F, NF, RGY CO,qT ADH IRTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 29 SCHEDULE DGL DECOR A T1VE GR Ol INT) I JGI-ITING (Effective 10/01/03) A PPI ,lC A TION Applicable to any customer using ground lighting served by the Ci~s electric distribution system for outdoor area lighting. The customer owns, operates, and maintains the decorative ground lighting upon installation by the City of Denton. NET MONTHI,¥ RATE (I) Facility Charge (Meter) $6.70 / 30 Days Facility Charge (Per Light) 50 W Sodium Vapor Beacon 50 W Spot 70 W Sodium Vapor Ballard 100 W Sodium Vapor Ballard (2) Energy Charge $2.15 / 30 Days $1.70 / 30 Days $4.50 / 30 Days $4.50 / 30 Days 3.79 cents / KWH TYPE OF ,qFRVICE The City shill furnish and install light fixtures, and deliver electric service to automatically controlled lighting fixtures conforming to the City of Denton's standards and subject to its published rules and regulations. The service is provided between dusk and dawn. TERM OF PFR I JGI-IT FACII,ITY CHARGES At the end of ten (10) years, the facility charges per light will be discont'mued. PAYMF, NT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days fi:om date of issuance. IN,qTAI J ,ATIONI COSTS The installation costs will be calculated by the City. The customer is responsible for installation costs at the City's discretion. 30 ~PEC~IAI ~ FA{~}] JT1]~,~ All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to the Special Facilities Rider. TF, RM OF CONTRACT A ten (10) year contract shall be agreed to and signed by the customer desiring Decorative Ground Lighting Service authorizing fixed monthly meter charges, which may be reviewed annually, and to be applied to the monthly municipal utilities bill. The monthly per light facility charge will not change during the ten (10) year contract period. In the event that a customer desired the removal of the trait or discontinuance of the service prior to completion often (10) years, the remainder of the contract period shall become due and payable. After the end of the initial ten (10) year contract, service shall continue on a month- to-month basis and may be canceled by either party upon thirty (30) days notice. PROR ATIONI OF 1 ITII ,TTY RTl ,T ..q Billing for the Facility charge shall be based on twelve (12) billings annually and prorated for longer or shorter billing periods using the following formula: Formula: Ac, mi da.va in reading period x Customer Facility Charge 30 days SCHEDULE TI TF, MPC~R ARY .qFR VI{21~ ,qt21-1FiDI TI (Effective 10/01/03) APPI,ICATION Applicable when a customer requests electric service on a short term or temporary basis where a customer has received a permit from the City of Denton's Building Inspections Department. This rate is not applicable after the certificate of occupancy has been issued. NI~T MONTHI ,¥ R A (1) Facility Charge SIngle-Phase Three-Phase (2) Energy Charge (3) Energy Cost Adjustment $15.15 / 30 days $20.20 / 30 days 6.77¢ / KWH Current ECA Schedule MINIM[ IM Rll J ,lNG Facility Charge. TYPI~ OF ,ql~.R VI'CF. At the City's available secondary supply. ADDITIONAL TF, MPOR ARY ,qF, RVIC, F, C, HARGF,.q Labor (Regular Time) $60.00 minimum up to 1 hour. $60.00 for each additional hour (to be measured to the nearest one-quarter hour). Labor (Overtime) $75.00 minimum up to 1 hour. $75.00 for each additional hour (to be measured to the nearest one-quarter hour). Premium time to be added where applicable. Transportation To be billed by hours or miles, a s applicable, according t o t he estimated cost of operating the equipment. 32 Material ,qPF. CIAI, FACl[ ,lTlg~,q Material that cannot be salvaged to be billed at stores cost plus 25% plus apphcable sales tax. At the time a temporary service is removed or converted, any loss in the material installed due to negligence or willful action by the customer will be billed separately to the customer at replacement cost plus 25% and sales tax. All services which require special facilities in order to meet the customer's service requirements shall be provided subject to the Special Facilities Rider. See Section 25-23(e) for the standard requirements. FI .AT R ATI~ TF.1MPOR ARY ,qF. RVIC, F. Applicable to new construction of underground residential electric service only. Rate: A flat fee of $195 per lot payable when the customer applies for temporary service. PRORATION OF l Fl'Il JTV glii J ~q Billing for the Facility charge shall be based on twelve (12) billings annually and prorated for longer or shorter periods using the following formula: Formula: Aetnal da?q in reading period x Customer Facility Charge 30 days ENF, R GY CI-IAR G~ Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH Rate F, Nr~,R GM CO,qT AD.II LqTIVU~.NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 33 SCHEDULE PI INT~.R R l ~PTIR[ ,F, PRIMAR¥ Effective 10/01/03) .APpl JC A TlObI Applicable t o a 11 customers taking pnmary service a t a firm power 1 oad exceeding 1,000 KVA during the months of June, July, August and September and is, by contract, provided service subject to load interruptions. The City retains the right to limit the number of customers on tins rate if the City's load reduction goals are met. NE, T MONTIqI.y CHARGE (Estimated Transmission Firm) (1) Facility Charge (2) Energy Charge (3) Demand Charge $70.70 / 30 days 0.2O¢ / KWH $3.78 / KVA (4) Energy Cost Adjustment Current ECA Schedule M1NIMI ~ lin ,I,ING An amount equal to the demand charge as calculated below but not less than one hundred percent (100%) of the maximum monthly KVA similarly determined during the previous billing months of May through October i n t he twelve months ending with the current month, nor less than 1,000 KVA. TYPF, OF .qF, R VIClq Interruptible primary voltage service (transformation equipment owned by customer) is available to any customer with a twelve (12)-month minimum monthly demand of 1,000 KVA or greater. Intermptible primary service rendered at one point on the customer's premises at a nominal voltage of 13,200 volts or 69,000 volts three-phase at the option of the utility. The primary voltage service customer shall own, operate, and maintain all facilities necessary to receive three-phase primary voltage service and all transformation facilities required for conversion to. utd~zatmn voltage. The C~ty shall own, operate and maintain all metering facilities, either at primary or secondary voltage, at the City's option. Where the City elects to meter at secondary voltage, two percent shall be added to the demand charge, the energy charge, and the energy cost adjustment charge to account for transformer losses. 34 DI~TF. RMTNATTON OF F)I~,MANT') The demand shall be det~mined by the KVA supplied during the fifteen (15) minute period of maximum use during the current month as determined by City's demand meter, but not less than 100% of the maximutn monthly KVA similarly determined during the billing months of May through October in the twelve months immediately preceding the current month, nor less than 1,000 KVA. ~pI~.CTAT, FAC. TI .lTlF(,~q All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to the Special Facilities Rider. PRORATION OF 11TII,1TY FIII,I (a) Billing for theFacilitychargeshallbebasedontwelve(12)billings annually and prorated for longer or shorter billing periods using the following formula: Formula: Ae~a] day~ in reading period x Customer Facility Charge 30 days (b) Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Formula: Antnal da? in reading period x KVA Demand x KVA Rate 30 days Billing for the energy charge shall be based on actual KWH consumption during the billing period. Formula: KWH x KWH Rate F, NI~,RCt¥ CO~qT ADH T~qTMF, NTT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 35 SCHEDULE ES ~qTANDI:tY; ~ql lPPI ,FMF, NTARY AND MA1NTF, NIANCF, ~qF, RVICF, (Effective 10/01/03) A PPI ,lC A TION Applicable in all areas served by the City to customers who: (1) Own and/or operate an electric power generation facility mainly used for non- emergency uses and which has a total nameplate or effective capacity (whichever is lesser) of fifty (50) KVA or more in parallel with the City's electric system for the purpose of generating power for the customer's own consumption, and (2) Employ equipment which is compatible with the Ci~s electric system at the customer's delivery point and which will cause no damage to the City's electric system or equipment or present undue hazards to City personnel, and (3) Own and/or operate an electrical generat'mg facility which has been certified annually by a registered professional engineer practicing in the utility or Independent Power Production Industry to be a functioning and reliable generating facility. (4) Operate an electrical power generafmg system at least 6,500 hours annually. (5) Execute an agreement for interconnection and parallel operation with the City. INTER CONINIF, CTION CORTR The customer shall reimburse the City for any equipment or facilities required as a result of the installation by the customer of generation in parallel with the City's electric system. The customer shall pay all costs of the City to extend its facilities or modify them at the time of interconnection, or at some future time in order to permit parallel operation of the customer's facility. TYPF, OF ~qF, RVICF, The City shall supply altemat'mg current at sixty (60) cycles and at the voltage and phase of the City's electric system most available to the location of the customer. The pr/mary voltage customer shall own, operate and mainta'm all facilities necessary to receive three-phase primary voltage service and all transformation facilities required for conversion to utilization voltage. The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage, at the City's option. Where the City elects to meter at secondary voltage, the secondary energy and on- peak demand charges shall apply. 36 Primary Secondary .%trice ~e:'viee (1) Facility Charge $60.60 / 30 days $25.25 / 30 days (2) Demand Charges: On-Peak Demand Off-Peak Demand $10.30 / KVA $3.80 / KVA $10.30/KVA $3.80 / KVA (3) Energy Charges: Non-Emergency Energy 0.20¢ / KWH Emergency Energy 5.25¢ / KWH 0.51¢ / KWH 5.35¢ / KWH (5) Energy Cost Adjuslment Current ECA Current ECA If the stun of the Customer Facility Charge, the On-Peak Demand Charge, and the Off-Peak Demand Charge is less than $1.00 per KVA of installed transformer capacity, $1.00 per KVA of installed transformer capacity will be the monthly charge. MINIMI [M FlU J ,lNG The minimum monthly billing shall be the higher of the following: (1) The sum of the Customer Facility Charge, the On-Peak Demand Charge, and the Off- Peak Demand Charge; or (2) A charge of $1.00 per KVA of installed transformer capacity. DF, TERMINATION Og ON-Pl~AK DFMAND The on-peak demand shall be determined by the KW demand supplied by the City during the fifteen (15) minute period o f maximum u se during t he o n-peak hours as recorded by the City's demand meter, but not less than one hundred percent (100%) of the maximum on-peak demand which occurred during the billing months of June through September in the twelve (12) months immediately preceding the current month. 37 DRTF~MINATIC)N OF ON-PEAK DEMAND - COGFNFR ATION 1 INITR NOT OPF/R AT1NG AND O.I IRTC)IM~RIR PEAK DID NOT C~ONTRTI:II ITE TO C. ITY'R ANNI IAI. RYRTI~M PRAK If a customer's cogeneration unit(s) is/are off during peak hours, and the customer's peak did not contribute to the City's annual off-peak demand, and the cogeneration unit is one (1) MW or larger, then the nameplate rating of the customer's unit(s) shall be deducted from the peak demand. The customer shall be charged the appropriate on-peak demand charges for the KW supplied by the City for the succeeding twelve (12) months. DFWERM1NATIONI OF OFF-PEAK (.q¥.qTEM) DFMAND The off-peak demand shall be determined by the sum of the KW demand supplied during the fifteen (15) minute period of maximum use as recorded by the City's demand meter, plus the KW nameplate rating(s) of the customers generator(s). In no event shall the off-peak demand be less than seventy percent (70%) of the maximum on-peak demand similarly determined during the billing months of June through September in the twelve (12) months immediately preceding the current month. DF:FERMINATION OF NTONI-FMERGENTO. Y F. NI:~.R GY All energy supplied to customers whose generating un/ts are less than one (1) MW capacity. DETFRIVIINATIOlq OF RMERGFNCY F. NF.R G¥ Emergency energy is all energy supplied by the City during peak hours of operation to displace energy normally supplied by the customer's one (1) MW or larger unit. DFiFINITION OF ON-PRAT( T4OT Ir.q The Cit)?s on-peak hours, for the purpose of this rate schedule, are designated as being fi.om 2:00 P.M. to ?:00 P.M. each Monday through Friday. DFFTTqlTIONT OF OFF-pF. AK lqOT TR ~q The City's off-peak hours, for the purpose of this rate schedule, shall be all hours not designated as on-peak hours. ,qpECTAI, FAC, IT,TTTE~q All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. 38 PROR ATTON OF I r'CH (a) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods using the following formula: Ac~ml day.q in reading period x Customer Facility Charge 30 days (b) Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Actual da? in reading period 30 days x KW Billing Demand x Rate ENTERGY CHARGE Billing for energy shall be based on actual KWH consumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block CREDIT FOR F.N-F(.RGY DRT.IVRRED INTO CITY'S RYST1R. M DIIR1NG ON-PEAK HOT 1R,q If Customer-produced energy is fed back into the City's system during on-peak hours, an mount equal to fuel cost calculated in accordance with Schedule ECA, as applicable to such energy is credited monthly, provided that Customer has paid the City for necessary added metering, protective and other equipment as determined by the City. CRI~DTT FOR F. NF.R CrY DRT.IVRRF. D INTO CIT¥'R .q¥.qT1RM DI I]~INIG OFF-PEAK l-lf)I YR R If Customer-produced energy is fed back into the City's system during off-peak hours, an amount equal to 70% of the billed ECA charge per KWH (for each KWH delivered back into the City's system) will be credited monthly, provided that Customer has paid the City for necessary added metering, protective and other equipment as determined by the City. F. NI~.RG¥ CO~qT ADJI I.qTMIR. NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 39 SCHEDULE AF A TI-ti ,~:'rTC ~,T ,D (Effective 10/01/03) APPT JCATION Applicable to all electric service metered at one point for use to light specified areas for athletic events where such electrical use will not occur between the hours of 2:00 P.M. and 7:00 P.M. for the months of June through September. NF,'T' MONTT-TI ,Y R ATF~ (1) Facility Charge Single-Phase Three-Phase (2) Energy Charge $20.20 / 30 days $30.30 / 30 days glilling mnnth~ nflune lhrnugh ~qeptemher: 2:00 PM to 7:00 PM (Peak) 7.58¢ / KWH All Other Hours (OffPeak) 3.79¢ / KWH glilllng month~q of OctoBer throll~h May,' All hours 3.79¢ / KWH (3) Demand Charge glilllng mc~nth~ of hme thrm]~h ~qeptemher~ Peak (2:00 PM - 7:00 PM) All Other Hours (OffPeak) $4.70 / KW $1.11/KW l:lilling mnnth~ nfOctnhe, r thrnngh May: All hours $1.11 / KW (4) Energy Cost Adjustment Current ECA Schedule 60 MlNIMI 1M gll J ,lNG Facility Charge TYPl~ OF At the City's available secondary voltage and available phase. For use only between the hours of 7:00 P.M. and 2:00 P.M. fi.om June through September and all hours fi.om October through May. ,qPF, CIAI, FAC, Il ,TT1T~,R All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PRORATION Cig 1 ITU ,ITY (a) Billing for the Facility charge s hall b e based o n twelve (12) billings annually and prorated for longer or shorter periods using the following formula: Formula: Aehml day~ in reading period x Customer Facility Charge 30 days (b) Billing for demand shall be calculated on a thirty (30) day per month basis and prorated for longer or shorter billing periods using the following formula: Formula: Aelnal dayg in reading period x KW Demand x Rate 30 days F~NTR G¥ C,I-I AR G[~ Billing for the energy charge shall be based on actual KWH consumption during the billing period: Formula: KWH in rate block x Rate per KWH in rate block F, NIT~.R G¥ CO,qT AD.II IRTMF, NT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. 41 SCHEDULE IDR IN!DI TRTRTAT. DI~VEI ,OPM~NT R ATF~ (Effective 10/01/03) AVAH,A~H,IT¥ This rider is available to the customers who receive service from Rate Schedules GSS, GSL, or TGS. A PPI JC A TION This rider is available to electric service supplied at any one location. It is for finn electric service applicable to new and existing customers as described below, over a five-(5) year period. This rider is available to the following classes of customers: (1) New customers whose electric service represents demand not previously served by the City at any location in the City's service area in the last twelve (12) months, where such metered demand will be in excess of 225 KVA or 200 KW, as estimated and mutually agreed upon by the Director of Electric Utilities and the customer. (2) Existing customers served under Rate Schedules G SS, G SL o r T GS w ho increase their prior existing metered demand by 225 KVA or 200 KW. Tins increase shall be verified by comparing a three-month rolling average of the new level of demand to the prior demand averaged for corresponding months. During periods in winch this verification method cannot be applied, the Director of Elec~c Utilities and the customer may develop a mutually agreed-upon formula to estimate the base and additional demand levels. NE, T MONTHI,¥ R ATE The customer shall be charged under the appropriate applicable rate schedules with the exception that the monthly billing demand (For GSS and GSL) or system demand and on-peak demand (for TGS) will be adjusted in accordance with the following table: Time Perind Reduction to Billing Demand or .qy.qtern Demand First Year 50% Second Year 40% Third Year 30% Fourth Year 20% Fifth Year 10% CONTR ACT Pl~R TOD The term of the contract will be for five (5) years. 42 SCHEDULE EP ~NI~R G¥~q A VF, PR OGR (Effective 10/01/03) APPT JCATION/PROGR AM ,qT IMMARY Denton Municipal Electric ("DIViE") through this program, called "EnergySave", is offering cash payments as incentives in the form of rebates to customers who purchase and install high-efficiency air conditioners or heat pumps for existing residential or commercial facilities. This program will also provide structure incentives in the form of rebates, in the amount of $2,000 per qualifying structure, to residential builders of single-family residences for meeting specific DME structure requirements. Satisfying these construction requirements will improve a residential structure's heating and cooling systems' operating efficiency. Apartments and multiple unit residential structures will qualify for the air conditioner rebates, but will not qualify for the structure incentive, if they meet the applicable EnergySave Program Guidelines. The EnergySave Program's objectives are primarily to reduce energy demand and consumption, thereby allowing the customers of DME to save dollars on their utility bills, reducing the peak load of the City of Denton's electric system, and promoting energy efficient heating and cooling. The EnergySave Program will be in effect each fiscal year beginning on October 1, until the allotted funding is depleted. At the time the funds are depleted, no additional applications for participation will be accepted until the next fiscal year. PROGRAM GT rlDF, I ,lN~,,,q I. Qualification Gnideline~ fnr I-IVAC F,o?ipment A. All installations must be for accounts served by the DME and must meet all applicable national, local, and manufacturers' codes and specifications. B. To qualify for the equipment incentive, the equipment must be new when installed. C. All equipment must be purchased. No leased or lease/purchased equipment Will qualify for a cash rebate. D. Installations must be made by licensed contractors and/or dealers. E. No rebate will be paid on a partial replacement of an air conditioner. The condenser unit and the evaporator coil must be replaced to qualify for a rebate. F. Requests for payment must be received by DME within thirty (30) days of installation. G. Equipment and installation must be permitted and inspected by the City's Building Inspection Department before final approval for payment is issued. The EnergySave Program guidelines and payments are subject to change by DME without prior notice. DME may, at any time, discontinue the EnergySave Program without prior notice. Payments shall be credited to the recipients' utility account with DME. II. Qualifieatlnn Gnideline~ for ~qtnmh~re Incentive A. $2,000.00 per qualifying structure is offered to a builder or authorized agent. B. Builder, or authorized agent, must be enrolled in the Denton Municipal Electric EnergySave Program (EnergySave). C. Each home participating in the EnergySave program must be registered with DME prior to constmction and must also comply with the 2000 IECC requirements relating to residential structures. D. Install a 1.5-ton or above central air conditioner or heat pump having a minimum efficiency rating of 14 SEER. E. Install minimum insulation off R49 - ceiling (uniform application) R30 - under decking R30 - cathedral or vaulted ceiling R30 - floor R13 - wall cavity Insulation should not contact radiant barrier roof decking. F. Exterior glass must meet minimum high efficiency standards 0.4 or below - solar heat-gain coefficient 0.4 or below - U-factor G. Programmable Thermostat - EnergyStar approved H. Radiant Barrier Decking Must maintain air gap between insulation and decking I. Acceptable attic ventilation One square inch of ventilation per square foot of attic floor, or rate of air exchange of entire volume of attic air once at per minute J. Structure Incentives for new homebuilders must also comply with the respective restrictions and guidelines set forth by the International Residential Code (IRC). III. General Prnnextl~re, n A. Application 1. Equipme~: An application for equipment incentive must be completed and sent to Denton Municipal Electric within sixty (60) days of installation of new or replacement equipment. Participating dealers have application forms and will complete these forms for the purchaser. It is the purchaser's responsibility to see that the dealer completes the form and submits it to DME. All submissions are subject to lawful verification of identification and entitlement to the EnergySave credit by Denton Municipal Electric. 2. Structure Incentive: To qualify for residential structure incentives, a builder/developer or authorized agent must be registered as an authorized Denton Municipal Electric EnergySave Authorized Builder. To become a recognized EnergySave builder, applicant must complete and submit a Denton Municipal Electric EnergySave Builder Application form to the Director of Electric Utilities. Applicant must also meet the requirements listed in the IECC and EnergySave guidelines. B. Inspections Installations of central air-conditioning systems must be permitted and will be inspected by the City's BuildIng Inspection Department, and must be approved before rebates will be processed. All submissions are subject to lawful verification of identification and entitlement to the EnergySave credit by Denton Municipal Electric. New structures will be randomly audited to insure adherence to the required energy efficient construction specifications. C. Payments to Participants 1. Equipment Retrofit (Existing residences) Cash payments will b e m adc t o t he purchaser o f t he qualifying replacement equipment. Parficipat'mg retail equipment dealers will receive a cash payment of $20 per trait for the sale of window units, central air conditioning systems, or heat pumps to offset their cost for properly filling out the applications for purchasers of retrofit equipment. All submissions are subject to lawful verification of identification and entitlement to the EnergySave credit by Denton Municipal Electric. 45 2. New equipment and structure incentive Program participants are responsible for submitting the correct information. DME will not issue any additional payment unless the payment was incorrect due to a mistake in processing by a City employee. The twenty-dollar ($20.00) payments to dealers will be made only if they supply the qualifying equipment to the customer or builder who is paying for the installation of the equipment. Dealers and purchasers may be denied payment for failure to follow program guidelines such as: failing to supply correct SEEIUEER figures; installing equipment which is not new; replacing part of a split system; or failure to fill out rebate forms properly. All submissions are subject to lawful verification of identification and entitlement to the EnergySave credit by DME. Payments will be made to customers who purchase and install new qualifying equipment. If a tenant purchases and installs qualifying equipment, the payment is made to the t chant. I f t he owner o f rental property purchases and installs qualifying equipment, the payment is made to the owner. IV. Payment Schedule Type nfl Init Central Air Conditioning Central Heat Pumps Geothermal Heat Pump Room Air Conditioners Room Heat Pumps SEER/EER Rating 14.0+ 14.0 + 14.0+ 12.0+ 12.0+ Incentive $600/unit $700/unit $700/unit $50/unit $50/unit SCHEDULE MTR PRD'.MII ]M-F, FFICI~,NCY MOTOR Rg, RATI~. (Effective 10/01/03) APPT ,TC, ATTON/PROGR AM RI TMMARY' The City of Denton Utility Department is offering cash payments to customers who purchase and install premium-efficiency motors and adjustable speed drives in facilities serviced by Denton Electric Utihty. The program's objective is to reduce energy demand a nd consumption, t hereby saving customers dollars on their utility bills and reducing the peak load of the City of Denton's electric system, thereby conserving energy and improving the power factor. Pl~ OGR AM Gl IID'IR, T ,INF,,S All installations must be for accounts served by the City of Denton Electric Utility and must meet all applicable national, local, and manufacturers' codes and specifications. To qualify for a rebate, equipment must be new when installed. All equipment must be purchased. No leased or lease/purchased equipment will qualify for a cash rebate. Removed motors must be properly disposed of after inspection and not re-used with the Denton Electric Utility system. Method of disposal must be stated. The City will pay the rebate to the purchaser of the quahfying equipment upon verification of compliance with program guidelines. Equipment and installation are subject to inspection by the City's Electric Utility before final approval for payment is issued. Replacement motors must be the same horsepower or lower than the original motor. Exceptions must be approved in writing by the City's Electric Utility. Only motors 20 horsepower and above are eligible for the program. All information must be complete on the Motor Rebate Application in order for a rebate to be issued (see Motor Rebate Application). The Premium-Efficiency Motor Rebate program guidelines and payments are subject to change without notice. This program may be discontinued with prior notice, at any time by the City of Denton Electric Utility. 47 Rebates for the Premium-Efficiency Motor Rebate Pro,ram will be based on the following methodology: I:~EPLACEIVI~NT MOTORS: 1. The Denton Elce~c Utility staff will visit the site to detenain¢ thc existing motor's efficiency. If the existing motor is non-operational, aa estimate will be m~de. 2. The customer must provide all information on the rebate application conceming the proposed motor purchase. 3. A new motor must not exceed the horsepower of the existing motor without express written consent by the Denton Electric Utility, which consent shall be given only if the utility finds aa increased efficiency. 4. The information concerning the existing and the proposed motors will be entered into the Motor Master software program to calculate the kilowatt (KW) or kilovolt amperes (KVA) savings yield. T he calculation i s based o n horsepower, efficiency, RPM, and load information. 5. The KW or KVA yield will be multiplied times the rebate incentive amount of $100/KW or $90/KVA: KW yield x $100/KW or KVA yield x $ 90 / KVA 6. The Denton Electric Utility will to the site to verify installation, and following successful installation, a rebate check will be mailed to the customer. NEW MOTORS: New motors will follow the procedure outlined above for replacement motors but the efficiency comparison will be made against a standard new motor, to be determined by the Motor Master software program used by the City, Department of Energy standards, or the Denton Electric Utility. ADJUSTABLE SPEED DRIVES: The Denton Electric Utility will visit the customer site to determine KW/KVA savings from the proposed Adjustable/Variable Speed Drive. Those savings will be awarded on a $100/KW or $90/KVA basis. A watt-meter will be used before and after installation. KW / KVA SAVINGS: Rebates in excess orS1,000.00 require advance approval of the Director of Electric Utihties. 48 SCHEDULE UPS 11KTIfN~RT ~PT1FI~I,F, POWER SI IPPI,Y (Effective 10/01/03) APPT ,TC ATTONT Applicable to any customer who, by written agreement, receives service for an uninterruptible power supply for a computer or other electrical equipment. Uninterruptible Power Supphes provided by the City of Denton are of the standby type. N~,T MONTHI,Y RATE (1) Facility Charge: 0 - 300 Watts Uninterruptible Power Supply 301 - 700 Watts Uninterruptible Power Supply 701 - 1,200 Watts Uninterruptible Power Supply (2) Installation Charge $7.80 / 30 days $14.90 / 30 days $31.85 / 30 days $25.75 For any Uninterruptible Power Supply other than above, the monthly customer charge will be based on the following formula: (1) Monthly Charge: 5% of Anmml Maintenance Cn~t 12 months 6% Annlml Reborn of Tnve,qtment 12 months 8% Interest on a 5 Year Life PLUS PLUS TYPE OF ~qF. RVIC, F, The City shall furnish, install, ma'mtain an automatically controlled altemating current power backup unit conforming to the City's standards and subject to its published roles and regulations. PAYMF, NT Bills are due when rendered, and become past due if not paid within fifteen (15) calendar days fi:om date of issuance. 49 All services which require special facilities in order to meet customer's service requirements shall be provided subject to the Special Facilities Rider. PRC}R ATTf~N OF I IT[[ ,1TV DI[[ J (a) Billings for the Facility charge shall be based on twelve (12) billings annually' and prorated for longer or shorter billing periods using the following formula: Formula: Actualday,~ in reading period x Customer Facility Charge 30 days 5O SCHEDULE ECA ENERGY C,O,~T AD~[ ~TMF, NT (Effective 10/0 !/03) ENERGY COgT ADH T~qTMENT All monthly KWH charges s hall b e increased o r decreased by an amount equal to "X" cents per KWH, to be known as the energy cost adjustment (ECA). The ECA shall be computed during the last month of each fiscal year quarter (December, March, June and September) to be applied to the quarter immediately following. The City shall in no case change the energy cost adjustment more than once in any three (3) month period. The ECA shall be calculated using the following formula: ECA = Prnjeetecl ener~oy en~t fnr next quarter Projected KWH sales for next quarter In the event that actual plus estimated cumulative costs of fuel, variable costs of Texas Municipal Power Agency (TMPA) energy and purchased energy (excluding TMPA's fixed charges) are greater than or less than the actual and projected ECA revenues by $500,000 or more during the next quarter, the Director of Electric Utilities or her designate shall recompute the Energy Cost Adjustment and, with Public Utilities Board approval, may establish an ECA that collects or returns such difference over the next three month period. Such change in ECA shall be applied evenly to each month during the three-month period. 51 (1) ~PEIqlAI, EACII,ITIES RIDER (Effective 10/01/03) All service shall be offered fi.om available facilities. If a customer service characteristic requires facilities and devices which are not normally and readily available at the location which the customer requests service, then the City shall provide the service subject to paragraph (2) of this rider. The total cost of all facilities reburied to meet the customer's load characteristics which are incurred by the City shall be subject to a special contract entered into between the Utility and the customer. This contract shall be signed by both parties prior to the City providing service to the customer. S2 l)lgeOlJ~T RI1}F,R FOR ~TATF, IIh'IVli, RglTII~,g AND (XIl.l]~.C'.i?,g (Effective 10/01/03) APPI' ,TC~ ATION Service provided herein is applicable to electric service billed under the otherwise applicable tariffed rate for service supplied to a facility of a "four year state university upper level institution, the University of North Texas, Texas Woman's University or college" as provided in Section 2.2141, under Subtitle E, Title II, Public Utility Regulatory Act of 1995. C.R F. DIT TO MONTHI ,Y BIll J, OR MONITHI.5" R ATI~ Customer's monthly bill and/or monthly rate shall be in accordance with the applicable rate schedule(s) in effect on July 1, 1997, shall be reduced by 20%. "Base Rates" are defined as the sum of the following charges: the Facility Charge, the Demand Charge, the Energy Charge and/or the adjustment for shorffextended read cycles of the applicable rate schedules. Base rates do not include recovei3, of fuel and purchased energy costs, including, without limitation, energy cost adjustments (the ECA rate or its successors). All other charges and calculations in the rate schedule are unchanged. The rates initially established on July 1, 1997 by this Discount Rider shall be the maximum or ceiling rate charged to the University of North Texas ("UNT") and Texas Woman's University ("TWU") during the term of the seven (7) year power supply agreement. If during the term of the power supply agreement any applicable tariffed "Base Rates" are reduced by more than 10%, the discounted rates for UNT and TWU will be reduced such that the discounted "Base Rates" are always at least 10% below any tariffs that will otherwise be applicable to the universities. At no time shall tariffed base rate decrease cause the rate discount to the two (2) universities to decrease by more than 50% over the term of the power supply agreement. S3 ~ That the Assistant City Manager for Utilities is hereby authorized to expend funds to issue rebates to electric utility customers in the form and type set forth in Schedules EP and MTR, as the use of more efficient air conditioning compressors, heat pumps, motors, and thermal storage is in the best interest of the City of Denton, as such will reduce the peak-load and conserve energy, which are public purposes of the City. ~qF, CTIONI 3. That all ordinances or parts of ordinances in force when the provisions of this ordinance became effective which are inconsistent, or in conflict with the terms or provisions contained in this ordinance are hereby repealed to the extent of any such conflict. ~qF. CTION 4. That if any section, subsection, paragraph, sentence, clause, phrase or word in this ordinance, or application thereof to any person or circumstances is held invalid by any court of competent jurisdiction, such holding shall not affect the validity of the remaining portions of this ordinance, and the City Council of the City of Denton, Texas, hereby declares it would have enacted such remaining portions despite any such invalidity. SECTION 5 That this ordinance and the rates herein adopted shall become effective, charged, and applied to all electric services rendered by Denton Municipal Electric, and all energy usage by customers of Denton Municipal Electric on and after October 1, 2003; and a copy of said rates shall be maintained on file in the Office of the City Secretary. PASSED AND APPROVED this the ~ fi---g dayof ~, ~ ,2003. EULINE BROCK, MAYOR ATTEST: JENNIFER WALTERS, CITY SECRETARY By: ~ APPROVED AS TO LEGAL FORM: HERBERT L. PROUTY, CITY ATTORNEY S:\Our Documents\Ordinances~03~Electric Rate Ordinance 2003.dec