Loading...
2002-004ORDINANCE NO. ~ffO~- ffO~ AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF DENTON, TEXAS AUTHORIZING THE CITY MANAGER TO EXECUTE CHANGE ORDER NUMBER THREE TO THE CONTRACT BETWEEN THE CITY OF DENTON AND ARCHER WESTERN CONTRACTORS, LTD.; PROVIDING FOR AN INCREASE IN THE SCOPE OF WORK AND AN INCREASE IN PAYMENT AMOUNT; PROVIDING FOR THE EXPENDITURE OF FUNDS THEREFORE; AND PROVIDING AN EFFECTIVE DATE [ORDINANCE NO. 2001-192; BID NO. 2612 - LAKE RAY ROBERTS 20 MGD WATER TREATIVlENT PLANT AWARDED TO ARCHER WESTERN CONTRACTORS, LTD. IN THE AMOUNT OF $35,785,257; PLUS CHANGE ORDER NUMBER THREE IN THE AMOUNT NOT TO EXCEED $71,328.36; WILL BE PAID FROM FUNDS WITHIN THE EXISTING CONTRACT (ALLOWANCE BB)]. WHEREAS, on May 1,2001 by Ordinance No. 200 I-192, the City awarded a public works contract to Archer Western Contractors, Ltd., in the mount of $35,785,257 for the construction of the Lake Ray Roberts 20 MGD Water Treatment Plant and related improvements; and WHEREAS, the Staff having recommended, and the City Manager having recommended to the Council that a change order be authorized to amend such contract agreement with respect to the scope of work, materials, labor and an increase in the payment amount, and said change order being in compliance with the requirements of Chapter 252 of the Local Government Code; NOW THEREFORE, THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS: SECTION 1. That Change Order No. Three, increasing the amount of the public works contract between the City and Archer Western Contractors, Ltd., which is on file in the office of the Purchasing Agent, in the amount of Seventy One Thousand Three Hundred Twenty Eight and 36/100 ($71,328.36) Dollars, is hereby approved and the expenditure of funds therefore is hereby authorized in accordance with said change order. The total purchase order amount remains at $35,785,257 and the funds allocated in the existing contract under Allowance BB thereto will be used for payment to Archer Western Contractors, Ltd. therefor. SECTION 2. That this ordinance shall become effective immediately upon its passage and approval. PASSED AND APPROVED this ~-~ day of ~/~~ ,2002. EULINE BROCK, MAYOR ATTEST: JENNIFER WALTERS, CITY SECRETARY By: APPROVED AS TO LEGAL FORM: HERBERT L. PROUTY, CITY ATTORNEY S:\Our Documen ts\Ordinanees\02LM'cher Western Change Order bio. 30rd.doc 2 FREESE o NICHOLS Lake Ray Roberts Water Treatment Plant City of Denton, Texas CHANGE ORDER PROJECT: OWNER: CONTRACTOR: Archer Western Contractor, Ltd. 201052 ENGINEER: Freese & Nichols, Inc. DNT00343 PROJECT NUMBER: CHANGE ORDER NO.: 003 DATE: 114/02 Make the following additions, modifications or deletions to the work described in the Contract Documents: · Provide and install two (2) dual rated primary transformers. (Service: 15kV ~ 25kV) · Change Order No. 003 is not to exceed $71,328.36 .See attached PCM-002 \ Primary Transformem · The compensation agreed upon in this Change Order is full, complete and final payment for all costs the Contractor may incuras a result of or relating to this change whether said costs are known, unknown, foreseen or unforseen at this time, including without limitation, any cost for delay, extended overhead, dpple or impact cost, or any other effect on changed or unchanged work as a result of this Chan~/e Order. Original Contract Amount Original Bid item \ Allowance BB Previously Approved Change Order Amount Previously Approved \ Allowance BB Amount Adjusted Contract Amount Proposed Change Order Amount Adjusted Bid Item \ Allowance BB Proposed Bid Item \ Allowance BB Revised Contract Amount Previous Contract Time Previous Substantial Completion Date Previous Final Completion Date Net Change in Contract Time Revised Contract Time Revised Substantial Completion Date Revised Final Completion Date ($700,000.00) ($578,940.85) ($507,612A9) $ 35,785,257.00 $ 121,059.15 $ (121,059.15) $ N/A $ 71,328.36 $ (71,328.36) $ 35,785,257.00 704 Days Februa~ 2003 April 2003 None N/A N/A N/A Recommended by FREESE AND NICHOLS, INC. [Date] Approved by '~'~wv ~u.E~ I-ID 'o~. [Date] Approved by Archer Western Contractor, Ltd. / ' [Date] PROJECT: Lake Ray Roberts Water Treatment Plant OWNER: City of Denton, Texas CONTRACTOR: Archer Western Contractors, Ltd. ENGINEER: Freese and Nichols ' SUBMITTAL TRANSMITTAL PROJECT NO. 201052 DTN00343 REFERENCE DATA: Contractor's Submittal No. PCM-002 Specification Section: 01380 Plan Sheet No: N/A Description: PRIMARY TRANS~ ' ,i,:/,(~ CONTRACTOR'S CERTIFICATION: I hereby certify that this submittal has been reviewed by the Contractor and is in strict conformance with the Contract Documents as modified by Addenda, Change DESCRIPTION Of Progress Shop Drawings Date: 12118/01 DATE RETURNED: #SENT #RTN'D o Approved O Approved as Noted O Not Approved O Revise & Resubmit O Filed as Received 1 '~Final Dis;ribution'~..~ l C~ Order Issue;sued.....~ O Field Order IssUed O Recommended for Approval O Returned W/O Review O Add'l Information Required O Canceled O See Review Comments COMMENTS: DISTRIBUTION SENT TO City of Denton - Fisher City of Denton - Field Freese & Nichols, Inc, FNI Field Office Montgomery Watson FOR ENGINEER'S USE ONLY I SENT TO DEPT REVIEW BY SENT RET'D FREESE" NICHOLS DEC 1 ? 2001 PROPOSED CONTRACT MODIFICATION ATTACHMENT A (4.41/) PROJECT: Lake Ray Roberts Water Treatment Plant OWNER: City of Denton, Texas CONTRACTOR: Archer Western Contractors, Ltd. ENGINEER: Freese & Nichols, Inc. PROJECT NUMBER: 201052 DNT00343 DESCRIPTION Primary Transformers NO. PCM-002 NOTIFICATION TO CONTRACTOR: The Owner proposes to make the additions, modifications or deletions to the Work described in the Contract Documents as shown in Attachment "A". We request that you take the following action within 10 calendar days: [] Notify us that you concur that this change does not require a change in Contract time or amount. A Field Order will be issued. Submit a Price/Credit Proposal with detailed cost breakdown of labor, materials, equipment and all other costs related to this change. Impacts on Contract Time shall be shown in a revised schedule, included with the submitted proposal. [] Proceed with the change. Payment will be made at the unit price bid. [] Proceed with the change under the time and materials provisions of the Contr~-ct. Authorization to proceed with changes must be approved by the Owner through Change Order in accordance with the Contract Documents. 'By: Steve Wilson _ Date: 12/17/01 CONTRACTOR'S RE,SPONSE: We respond to your request'as follows: [] By: We propose that this is a no cost or time change. Issue Field Order. We submit the attached Price/Credit Proposal with detailed cost breakdown~0i~ ~l~.for performing the described change. We are proceeding with the change at the unit price bid. We are proceeding with the change under the time and materials provisions of the C~,~.~. ~ ~ Date: / ACTION TAKEN: Proposed Contract Modification rejected. See comments. Field Order will be issued. Che~ Order will be_issued. FREESE* NICHOLS PROPOSED CONTRACT MODIFICATION ATTACHMENT A (4.4~ / ) The Owner proposes to make the following additions, modifications or deletions to the work described in the Contract Documents. Authorization to proceed with these changes must be approved by Field Order or Change Order in accordance with the Contract Documents, prfor to commencing the work involved. Comments: 1) Provide pdmary cable insulation class for 25kV. 2) Provide dual rated transformers that Would be required to allow the 24.94 kV on the primary. By: Steve Wilson - - Date: 17./17101 LAKE RAY ROBERTS WTP AUBREY, TEXAS PENDING CHANGE REQUEST COST ANALYSIS To ~ compk~d by Coeaeral Contractor or SubconU'a~'tor as outlined in the Uniform C_~gtal Conditions gw.~lan 6.6.1 Work performed by:. ( ) Ganeral CouUactor ( X ) Sulxanu'ac~x PROIECT: LAKE RAY ROBERTS WTP Tia~ ~ (iF ~): Description of Change: 25KV UPORADB PCM~: CPl.: R~I#: ASI#: 2 ADDITIONS A_,ND/OR [CREDITS] EX:i~,~I$ION A B C D I~ri~tian ~tit~ UnR Cost/~ait Ms~erlal I.~lmrEquip, T~-- S~ 25KV P~ ~ ~~ 2 ~ ~.~ $I~.~ S~,~ $120.~ 25KV ~Y 8~ 2 EA $II,~.~ ~1~6~,00 ~.~ $216.00 ~.80 25KV ~ t~ ~ ~S~OR 2 EA $1~620.~ . $3,120.~ $120.00 $31.20 $1,20 2~V C~A~ON S~DY I EA ~,~.00 i $~6~.00 $0.~ $36.00 $0.~ ~50 2~V 133% ~0 1,~ ~ $528.~ $9~504.~ ~.~ $95.~ $0.~ 5' PVC COA-/~ ~ ~W 4 EA $382.73 $1~70,51 ~.~ $12.71 ~.~ ~N~ 10 ~ $105.00 $9~.~ $150.~ $9.00 $1.50 p~O DU~ B~" I EA $960.~ $0.~ $960.00 $0.~ $9.60 S~ $52,511.23 ~,~8.80 g.~ $525.11 Line 1: Enter total of Columns A+B+C+D Liuo II: If Line I indicates an ADD. Eater 15% of Line I. If Line I indicat~ CREDIT, e~r -0- Line Iff: Enter ~ Col 1~ ($toxago) $55~943.93 $8t391.59 $29 Line IV: Ent~ 40.4% of Col B for Worlrm~n'S Comp. Social gecurity, and ~ tax~ Linc V: Tolal Line I tltm Line 1V K.~r here and on ~umnasy Sheei $1~163.04 __ $65,527.35 _ SIGNATURE._' ...... SIGNATURE: CONTRAC~)R / 8UBCON'rRAC'IDR DATE: DATI~: TOTIqL P. 02 i FIELD CHANGE JUSTIFICATION i I II PROJECT LAKE RAY ROBERTS I CI~( AUBREY DATE: 12/18101I COUNTY DENTON [ ITEM OF WORK DUAL VOLTAGE PRIMARY TRANSFORMER I ! I ESTIMATED QUANTITY I'LUMPSUM ! I DESCRIPTION QUANTITY PRICE LABOR MATERIAL EQUIPMENT i SUB LABOR I 72 $ 16.00 $ 1,152.00 I 55%INSURANCE AND TAXE~¢ $ 633.60 15% COMPENSATION $ 95.04 TOTAL LABOR COST $ 1,880.64 MATERIAL CONCRETE 8 S 70.00 i $ 560,00 I 05$ [ 05 I os I SUSTOTAL I i i I i S 560.00 i 15% COMPENSATION ; I I iS 84.00! i I TOTAL MATERIAL DOST i i I $ 644.60 I EQUIPMENT ! II i i' ,SUBTOTAL i I I $ i 15% COMPENSATION $ tOTAL EQUIPMENT COST I I $ , 6UBCONTRACTOR I ~ I PERATrACHED $ 65,527,35 t SUBTOTAL I I S 65'527'353,276.37 5% COMPENSATION I $ TOTAL SUBCONTRACTOR COST I Ii $ 68,803.72 I I I 71,326.36 TOTAL DOST OF FIELD CHA.GE ITEM $ I ' IINrr PRICE OF FIELD CHANGE ITEM $ 71.328.36 I I I I I ~ I I PLEASE NOTE THAT OWNER IS RESPONSIBLE FOR ANY IMPACT THIS CHANGE MAY HAVE ON COMPLETION DATE OF PROJECT